Power Driver
Phillips Bit
Torque Wrench
5 mm Hex bit
8 mm Hex bit
Parts Included
Tools Required
HermanMiller
Motia
TM
Sit-to-Stand Table
Installation
How to assemble your table.
Worksurface
Corner Worksurface
Stiffener
Glide
Rectangle
Control Box
Corner
Control Box
Top Mounting
Plate
Corner
Mounting
Plate
Corner Foot
Corner Adapter
Leg
Switch
Tapping Screw
Cable Holder
Power Cord
Cap Screw
Socket Screw
IMPORTANT SAFETY INSTRUCTIONS
When using an electrical furnishing, basic precautions should always be followed,
including the following:
Read all instructions before using this furnishing.
DANGER
- To reduce the risk of electric shock always unplug this furnishing from
the electrical outlet before cleaning.
WARNING
- To reduce the risk of burns, fire, electric shock, or injury to persons:
Close supervision is necessary when this furnishing is used by, or near children,
invalids, or disabled persons.
Sitting or standing on product may cause risk of personal injury (use for chairs,
tables consider obvious misuse of product).
Use this furnishing only for its intended use as described in these instructions.
Do not use attachments not recommended by the manufacturer.
Never operate this furnishing if it has a damaged cord or plug, if it is not working
properly, if it has been dropped or damaged, or dropped into water. Return the
furnishing to a service center for examination and repair.
Failure to fully tighten screws (bolts) may cause injury by causing Motia tables to
collapse. Tighten screws (bolts) until they stop plus a quarter turn.
Periodically check to make sure legs are properly aligned. Failure to do so may
cause risk of personal injury.
If using power drive set on low torque.
Keep the cord away from heated surfaces.
Never drop or insert any object into any opening.
Do not use outdoors.
Do not operate where aerosol (spray) products are being used or where
oxygen is being administered.
This furnishing is intended for commercial use
control box rating: 5.0A, 120V
Duty cycle: 2 min on, 18 min off
WARNING
- Risk of Electric Shock – Connect this furnishing to a properly
grounded outlet only. See Grounding Instructions.
For loading always put heavier items in the center and distribute the load.
Risk of Injury - Maximum Load 250 lbs (113 kg).
GROUNDING INSTRUCTIONS
This product must be grounded. If it should malfunction or breakdown,
grounding provides a path of least resistance for electric current to reduce
the risk of electric shock. This product is equipped with a cord having an
equipment-grounding conductor and a grounding plug. The plug must be
plugged into an appropriate outlet that is properly installed and grounded in
accordance with all local codes and ordinances.
T Foot
C Foot
Assembly Instructions
1
HermanMiller for Motia
TM
Table
1BGGNR rev K