3.1  Connection the gas lines

 

 

 

You can determine where the gas pipes will be placed, depending on the positioning of the appliance.  
Ensure control equipment is not twisted during installation and there is no excessive tension.  

Accessibility of various connection points in relation to components need to be maintained.  
After installation, check the connections for gas leakage. Use a 3/8“ gas tap in the main gas supply.  

Ensure the gas pipes are dirt-and sand-free. 

The gas connection should only be done without  

any excessive tension in the tubes etc. This prevents any damage occurring to the gas control equipment.  

 

3.2   Preparation and installation  

 

Open the door. 

Remove the packaging and check the unit for possible damage. 

Please note: place the unit on a stable surface. 

Do not place the unit on its back/side! 

Place the unit at the installation location  

Take all the packaged components out of the unit and check to make sure they are not  

 

damaged or broken. 

Situate the unit (see Appendix 2 as an example of an installation location) in your chosen  

 

installation location.  

*  

The adjustable feet allow to adjust the device more refined. 

 

 

3.3  Fitting the ceramic log inset (see Appendix 3)

 

 

 

 

Method: 

 

Spread the glowing material (lava granules) evenly over the burner and the burner decoration plate  

 

so that they  are just covered. Glowing embers can be placed here and there as decoration.  

Place the ceramic wood blocks in the correct order as shown on Appendix 3. 

Place the logs carefully. Other location can seriously affect the flames or malfunction of the  

 

burn process (sooting) 

Slot/opening between burner and mesh deco plate must be kept free of glowing material.

 

Before closing the door make sure if there must be a restriction plate to be placed or not. 

 

See chapter 7 

"Concentric chimney lay out" 

 

If there is a restriction required for your situation, remove the baffle plate by unscrewing it  

 

from the front of the plate and move the plate backwards and then out. Now install the restriction  

 

 plate with two screws and replace the baffle plate. 

Close the door. 

NOTICE 

Before installing the device it is recommended to first read Chapter 7  

"Concentric flue system" 

to consult.

 

3.   PLACING THE APPLIANCE 

Notice 

MAKE SURE THE PILOT LIGHT REMAINS UNOBSTRUCTED! 

Note: 

when installing the log set and the various glowing materials and accessories, the following must 

be taken into account:

  

A: 

  No glowing material in or on the pilot burner. 

B: 

  Prevent that ceramic material falls on the glass seals. Remove this if necessary. The window can be damaged. 

C: 

 

Slot /opening between burner and mesh deco plate must be kept free of glowing material. Too 

much placed glowing material can affect the combustion process.  

Summary of Contents for Harmony 25

Page 1: ...Pag 1 OPERATING AND INSTALLATION INSTRUCTION STANFORD HARMONY 25 STANFORD HARMONY 35 UNITED KINGDOM UK IRELAND IE...

Page 2: ...as lines 3 2 Preparation and installation 3 3 Fitting the ceramic logs 4 TECHNICAL DETAILS GV60 Page 9 5 INSTRUCTIONS FOR MERTIK MAXITROL GV60 GASCONTROL Page 10 6 GAS TECHNICAL DATA Page 11 7 CONCENT...

Page 3: ...fter the batteries have been inserted press the OFF button and small at the same time to toggle between F and 12 hour clock and C and 24 hour clock Wait a moment or press OFF to return to MAN mode 1 4...

Page 4: ...ited the flame will adjust to its maximum height automatically 1 7 Possible error messages Long sound signals during ignition Receiver batteries are almost empty After this signal is heard the unit ma...

Page 5: ...ly 1 10 Inserting and replacing the batteries The manual transmitter and receiver batteries have a life span of approximately one year The use of alkaline batteries is recommended The batteries need t...

Page 6: ...able to see whether the pilot flame is burning through the glass window If the pilot flame is alight keep the metal circle pressed down for another 10 seconds and then let go Turn the operating butto...

Page 7: ...d check whether the burner flame is uniform After the unit has been used for the first time you should remove any deposits resulting from Running burning in the paint using a glass cleaner for heaters...

Page 8: ...over the burner and the burner decoration plate so that they are just covered Glowing embers can be placed here and there as decoration Place the ceramic wood blocks in the correct order as shown on A...

Page 9: ...gory C11 C31 C91 Combustion gas discharge and Combustion air supply Concentric 100 150 mm 4 TECHNICAL DETAILS GV60 Main valve knob Thermocouple connection Pressure regulator Ignition connection Pilot...

Page 10: ...control block should be turned to the ON position The I 0 switch should to be set to I The ignition must be connected to the receiver box at the terminal SPARK The transmitter s contains the thermosta...

Page 11: ...MBAR 20 Mbar 20 25Mbar 30 30 37 30 Mbar BURNERPRESSURE HIGH MBAR 18 5 18 28 9 BURNERPRESSURE LOW MBAR 3 6 3 11 INJECTOR SIZE MM 1 9 2 1 1 15 INJ PILOTBURNER CODE 51 51 30 LOWSETTING SIZE MM 1 7 1 7 1...

Page 12: ...striction Baffle plate 0 3 meter no yes 3 7 meter 30 mm yes 7 12 meter 50 mm yes Vertical path with bends 45 X total Y 3 6 meter 30 mm yes 45 X total Y 6 12 meter 50 mm yes 90 X total Y 4 6 meter 30 m...

Page 13: ...ue should be cased if necessary Sufficient fireproof measures must also be taken when the flue is being mounted along flammable materials Determine the position of the unit and outlet and begin constr...

Page 14: ...is in place using 2 parkers Level the bottom side of the adjustable pipe 5 with the ceiling of existing chimney Shorten the flexible hose to approximately 100 mm above the existing chimney top Attach...

Page 15: ...ow Floor ceiling support Fire stop plate flat Concentric element Wall bracket Floor support Fire stop plate flat Locking band 9 Roof terminal 8 Locking band 7 Chimney connection set Renovation kit 6 F...

Page 16: ...receiver range limited 1 Move antenna cable see instructions 2 Replace receiver Optional wall switch cabling not operating properly Replace wall switch cabling Receiver fuse blown in older versions on...

Page 17: ...es not react Press RESET button see instructions Add ground wire between pilot burner and gas valve Do not coil the IGN cable Shorten IGN cable if possible NO IGN sequence stops no pilot flame Transmi...

Page 18: ...ver does not react Press RESET button see instructions Add ground wire between pilot burner and gas valve OK Do not coil the IGN cable Shorten IGN cable if possible 7 Main burner is lit NO Gas valve m...

Page 19: ...instructions The main burner goes out when the unit is warm 1 This can be a normal effect of the thermostat Check whether the pilot flame is able to heat the thermocouple adequately If the pilot flam...

Page 20: ...Pag 20 APPENDIX 1 DIMENSIONAL DRAWINGS Stanford Harmony 25 TOP CONNECTION Stanford Harmony 35 TOP CONNECTION...

Page 21: ...s A combustible shelf may be fitted over the appliance if in the case of a 150mm or less deep shelf there is at least 280mm clearance above the top of the stove The shelf depth may increase at the sam...

Page 22: ...Pag 22 APPENDIX 3 FITTING LOG SET Stanford Harmony 25 NG LPG...

Page 23: ...Pag 23 Stanford Harmony 35 NG...

Page 24: ...24 Industrias Herg m S A Soto de la Marina Cantabria Espa a Stanford Harmony 35 LPG Place behind the horizontal log embers to break the high pointed flame Place embers under the open space Horizontal...

Reviews: