Pag.6
MANUAL CONTROL
(In case of emergency, only applies to non remote control function)
The unit may be operated by hand if there is a defect in the remote control. To do so, the ignite (piezo) cable
of the receiver must first be removed and carefully slid into the piezo connector on the gas control block.
1.11 Igniting the fire
*
Open the gas shut-off cock that has been installed in the gas pipe to the unit.
*
Press the “
O I
” switch, on the gas control block, in the “
I
” position.
*
Turn the motor button, on the gas control block, completely to the right.
The button will make a "click” sound.
*
Turn the operating button on the gas control block, into the “
MAN
” position.
A metal circle in the operating button will become visible.
*
Push the metal circle inwards. For example, with a pen. Gas will now flow to the pilot flame.
*
While keeping the metal circle pressed down, press the (square) piezo button
(along the “
O I
” switch) several times to ignite the pilot flame. You will be able to see whether
the pilot flame is burning through the glass window.
*
If the pilot flame is alight, keep the metal circle pressed down for another 10 seconds and then let go.
*
Turn the operating button to the
ON
position. The burner may or may not ignite, depending on the
position of the motor button.
*
By turning the motor button to the required setting to the left, the burner will ignite and the
flame size can be adjusted.
1.12 Extinguishing the fire
Turn the motor button, on the gas control block, completely to the right. The button will make a "click” sound.
The burner will turn off. The pilot flame continues to burn.
1.13 Switching the unit off
Press the "
O I
” switch, on the gas control block, in the “
O
” position. The pilot flame will extinguish.
If the fireplace is not used for an extended period of time, we recommend closing the gas shut-off cock
in the supply line.
Piëzo Knop
Piëzo Ignitter
(Manual)
Manual knob
Main valve knob
Microswitch
“
O I
” Switch
8
Wire Receiver
Small metal circle for
Manual ignition
(Combination Control, Cover Manual position)
If, for whatever reason, the pilot light goes out, you must wait 5 minutes before reigniting it.
NOTICE