background image

Pag.6 

MANUAL CONTROL 

 

(In case of emergency, only applies to non remote control function) 

 

The unit may be operated by hand if there is a defect in the remote control. To do so, the ignite (piezo) cable  
of the receiver must first be removed and carefully slid into the piezo connector on the gas control block. 

 
 
 

 
 

 
 

 
 

 

 

 

 
 
 

 
 

 

1.11 Igniting the fire 

*  

Open the gas shut-off cock that has been installed in the gas pipe to the unit. 

*  

Press the “

O I

” switch, on the gas control block, in the “

I

” position. 

*  

Turn the motor button, on the gas control block, completely to the right.  

 

The button will make a "click”   sound. 

*  

Turn the operating button on the gas control block, into the “

MAN

” position.  

 

A metal circle in the operating button will become visible. 

*  

Push the metal circle inwards. For example, with a pen. Gas will now flow to the pilot flame. 

*  

While keeping the metal circle pressed down, press the (square) piezo button  

 

(along the “

O I

” switch) several times to ignite the pilot flame. You will be able to see whether  

 

the pilot flame is burning through the  glass window. 

*  

If the pilot flame is alight, keep the metal circle pressed down for another 10 seconds and then let go. 

 

*  

Turn the operating button to the 

ON

 position. The burner may or may not ignite, depending on the  

 

position of the motor button. 

*  

By turning the motor button to the required setting to the left, the burner will ignite and the  

 

flame size can be adjusted. 

 

1.12 Extinguishing the fire 

 

Turn the motor button, on the gas control block, completely to the right. The button will make a "click” sound.  

 

The burner will turn off. The pilot flame continues to burn. 

 

1.13 Switching the unit off 

 

Press the "

O I

” switch, on the gas control block, in the “

O

” position. The pilot flame will extinguish. 

 

If the fireplace is not used for an extended period of time, we recommend closing the gas shut-off cock  

 

in the supply line. 

 

 

Piëzo Knop 

Piëzo Ignitter 

         (Manual) 

Manual knob 

Main valve knob 

Microswitch 

O I

” Switch 

Wire Receiver 

Small metal circle for  

Manual ignition   

(Combination Control, Cover Manual position)

 

 

If, for whatever reason, the pilot light goes out, you must wait 5 minutes before reigniting it.  

NOTICE 

Summary of Contents for Harmony 25

Page 1: ...Pag 1 OPERATING AND INSTALLATION INSTRUCTION STANFORD HARMONY 25 STANFORD HARMONY 35 UNITED KINGDOM UK IRELAND IE...

Page 2: ...as lines 3 2 Preparation and installation 3 3 Fitting the ceramic logs 4 TECHNICAL DETAILS GV60 Page 9 5 INSTRUCTIONS FOR MERTIK MAXITROL GV60 GASCONTROL Page 10 6 GAS TECHNICAL DATA Page 11 7 CONCENT...

Page 3: ...fter the batteries have been inserted press the OFF button and small at the same time to toggle between F and 12 hour clock and C and 24 hour clock Wait a moment or press OFF to return to MAN mode 1 4...

Page 4: ...ited the flame will adjust to its maximum height automatically 1 7 Possible error messages Long sound signals during ignition Receiver batteries are almost empty After this signal is heard the unit ma...

Page 5: ...ly 1 10 Inserting and replacing the batteries The manual transmitter and receiver batteries have a life span of approximately one year The use of alkaline batteries is recommended The batteries need t...

Page 6: ...able to see whether the pilot flame is burning through the glass window If the pilot flame is alight keep the metal circle pressed down for another 10 seconds and then let go Turn the operating butto...

Page 7: ...d check whether the burner flame is uniform After the unit has been used for the first time you should remove any deposits resulting from Running burning in the paint using a glass cleaner for heaters...

Page 8: ...over the burner and the burner decoration plate so that they are just covered Glowing embers can be placed here and there as decoration Place the ceramic wood blocks in the correct order as shown on A...

Page 9: ...gory C11 C31 C91 Combustion gas discharge and Combustion air supply Concentric 100 150 mm 4 TECHNICAL DETAILS GV60 Main valve knob Thermocouple connection Pressure regulator Ignition connection Pilot...

Page 10: ...control block should be turned to the ON position The I 0 switch should to be set to I The ignition must be connected to the receiver box at the terminal SPARK The transmitter s contains the thermosta...

Page 11: ...MBAR 20 Mbar 20 25Mbar 30 30 37 30 Mbar BURNERPRESSURE HIGH MBAR 18 5 18 28 9 BURNERPRESSURE LOW MBAR 3 6 3 11 INJECTOR SIZE MM 1 9 2 1 1 15 INJ PILOTBURNER CODE 51 51 30 LOWSETTING SIZE MM 1 7 1 7 1...

Page 12: ...striction Baffle plate 0 3 meter no yes 3 7 meter 30 mm yes 7 12 meter 50 mm yes Vertical path with bends 45 X total Y 3 6 meter 30 mm yes 45 X total Y 6 12 meter 50 mm yes 90 X total Y 4 6 meter 30 m...

Page 13: ...ue should be cased if necessary Sufficient fireproof measures must also be taken when the flue is being mounted along flammable materials Determine the position of the unit and outlet and begin constr...

Page 14: ...is in place using 2 parkers Level the bottom side of the adjustable pipe 5 with the ceiling of existing chimney Shorten the flexible hose to approximately 100 mm above the existing chimney top Attach...

Page 15: ...ow Floor ceiling support Fire stop plate flat Concentric element Wall bracket Floor support Fire stop plate flat Locking band 9 Roof terminal 8 Locking band 7 Chimney connection set Renovation kit 6 F...

Page 16: ...receiver range limited 1 Move antenna cable see instructions 2 Replace receiver Optional wall switch cabling not operating properly Replace wall switch cabling Receiver fuse blown in older versions on...

Page 17: ...es not react Press RESET button see instructions Add ground wire between pilot burner and gas valve Do not coil the IGN cable Shorten IGN cable if possible NO IGN sequence stops no pilot flame Transmi...

Page 18: ...ver does not react Press RESET button see instructions Add ground wire between pilot burner and gas valve OK Do not coil the IGN cable Shorten IGN cable if possible 7 Main burner is lit NO Gas valve m...

Page 19: ...instructions The main burner goes out when the unit is warm 1 This can be a normal effect of the thermostat Check whether the pilot flame is able to heat the thermocouple adequately If the pilot flam...

Page 20: ...Pag 20 APPENDIX 1 DIMENSIONAL DRAWINGS Stanford Harmony 25 TOP CONNECTION Stanford Harmony 35 TOP CONNECTION...

Page 21: ...s A combustible shelf may be fitted over the appliance if in the case of a 150mm or less deep shelf there is at least 280mm clearance above the top of the stove The shelf depth may increase at the sam...

Page 22: ...Pag 22 APPENDIX 3 FITTING LOG SET Stanford Harmony 25 NG LPG...

Page 23: ...Pag 23 Stanford Harmony 35 NG...

Page 24: ...24 Industrias Herg m S A Soto de la Marina Cantabria Espa a Stanford Harmony 35 LPG Place behind the horizontal log embers to break the high pointed flame Place embers under the open space Horizontal...

Reviews: