Fig. 1
Fig. 2
Fig. 3
Fig. 4
ATTENTION! Make sure that the appliance is unplugged before handling any electrical parts.
To change the ventilators proceed as follows:
3. DISMANTLING THE VENTILATOR
4. ELECTRICAL OUTLINE
B
A
M.V.
220V.
50Hz.
22W.
220V.
50Hz.
22W.
M.V.
L
N
T
Term. 50ºC
1. Take out ash pan “A”.
(Figs 1 and 2)
2. Loosen the tw o screws that
attach the ventilator support (fig 3).
3. Remove the ventilator by
tilting it slightly (fig 4).
Disconnect the faston terminals
of the ventilator.
4. Replace the ventilator and
put it back in position by
follow ing
the
above
instructions but in the reverse
order.