Operational Specifications
Operating Temperature Range:
-40°C to +60°C (-40°F to +140°F)
Humidity:
5% to 95% (non-condensing)
Environmental Air:
No corrosive gasses permitted
Shock and Vibration:
N/A
Enclosure Type:
Unsealed
Agency Approvals:
N/A
Wiring Type:
Screw terminal block
Power Requirements:
2.25 VDC
– 2.75 VDC, 70 mA (max)
Output Signal Type:
Simulates 3mV/V 360 ohm load cell.
Maximum Output Signal Range:
-1.0 mV/V to +4.5 mV/V
Default Output Value:
-1.0 mV/V
Maximum Load Capacitance:
No limit
Zero Accuracy:
+/- 35 mV/V
Span Accuracy:
+/- 0.2% of reading
Linearity Error:
+/- 0.02% of full-scale
Span Temperature Stability:
+/- 35 ppm/°C
Output Signal Resolution:
.092 mV/V
Output Signal Ripple:
.046 mV/V
Serial Communication Interface Type:
HerdStar optically isolated (proprietary)