EN
– Translation of the original user manual - 2.0 | 2019
44
Fig.
no.
Terminal
no.
Designati
on
Input function
11.1
1
24
V ¯|_|¯
Output test signal (e.g. for light barrier)
11.2
2
LB in
Input signal from the light barrier
The upper left-hand terminal no. 1 with the designation “24V ¯|_|¯” is a 24-volt
supply, which is briefly switched off at periodic intervals for test purposes. The
transmitter of a light barrier, for example, can be connected to this power supply.
The function of the light barrier input signal is checked during the brief switch-off
phase.
Illustration 9:
Connection of tested one-way light barrier
Illustration 10:
Connection of reflex light barrier
The two representations show, as examples, the different connections of a one-
way light barrier tested by blocking the transmitter and an untested reflex light
barrier.
Connecting a light barrier
6.5.5
A one-way light barrier, as connected in the installation overview in Section 6.5.6,
is installed and parameterised in the following way:
De-energize the control system.
Fit the transmitter and receiver of the light barrier in a mechanically sound
manner.
Connect both modules to the 0 V of the electrical power supply and 24 V
from the control system.
Connect the signal line from the receiver module to the ‘LB in’ terminal.
Summary of Contents for HMD Basic
Page 2: ...EN Translation of the original user manual 2 0 2019 2...
Page 75: ...EN Translation of the original user manual 2 0 2019 75 Appendix A Declarations Dop DoC...
Page 76: ...EN Translation of the original user manual 2 0 2019 76...
Page 77: ...EN Translation of the original user manual 2 0 2019 77 Appendix B ELECTRIC DIAGRAM HMD24...
Page 78: ...EN Translation of the original user manual 2 0 2019 78...
Page 79: ...EN Translation of the original user manual 2 0 2019 79...
Page 80: ...EN Translation of the original user manual 2 0 2019 80...
Page 81: ...EN Translation of the original user manual 2 0 2019 81...
Page 82: ...EN Translation of the original user manual 2 0 2019 82...
Page 83: ...EN Translation of the original user manual 2 0 2019 83...
Page 84: ...EN Translation of the original user manual 2 0 2019 84...
Page 85: ...EN Translation of the original user manual 2 0 2019 85...
Page 86: ...EN Translation of the original user manual 2 0 2019 86...
Page 87: ...EN Translation of the original user manual 2 0 2019 87...
Page 88: ...Local supplier stamp Lokal terf rs ljare st mpel...