Heraeus Digilance V Instructions And Operating Manual Download Page 6

 

 

 

Page 4 of 21                                           Digilance V

                                             

 26 November 2018 

 

 File name:

 

Digilance V_1.01

 

 

Version: 1.01

 

1  Safety and usage notes 

1.1  General 

This manual provides the information required to use the instrument. It is written for technically qualified 
personnel such as engineers, programmers, or maintenance specialists who have been specially trained and 
who have the specialized knowledge required in the field of instrumentation, electronics, and control. 

This manual is an integral part of the instrument or device even if, for logistical reasons, it has to be ordered 
separately. For the sake of clarity, not all details of all versions of the instrument or device are described, nor can 
it cover all conceivable cases regarding installation, operation, and maintenance. If you require further 
information, or face special problems that have not been dealt with in sufficient detail in this manual, contact 
Heraeus Electro-Nite. 

We would also point out that the contents of this manual shall not become a part of, or modify, any prior or 
existing agreement, commitment, or legal relationship. The Purchase Agreement contains the complete and 
exclusive obligations of Heraeus Electro-Nite. Any statements contained in this manual do not create new 
warranties or restrict the existing warranty. 

1.2  Qualified personnel 

Only qualified personnel should be allowed to work on this instrument or device. Non-compliance with the 
warnings contained in this manual or appearing on the instrument or device itself can result in severe personal 
injury or damage to property. Qualified personnel include: 

 

System planning and design engineers who are familiar with the safety concepts of automation equipment, 
instruments, or electronic devices. 

 

Operating personnel who have been trained to work with automation equipment, instruments, or electronic 
devices, and are conversant with the content of the manual in as far as it is connected with the actual operation 
of the instrument or device. 

 

Commissioning and service personnel who are trained to repair such equipment, instruments, or electronic 
devices, and who are authorized to energize, de-energize, clear, ground, and tag circuits, equipment, and 
systems in accordance with established safety practices. 

1.3  Danger notices 

The notices and guidelines that follow are intended to ensure personal safety, as well as protecting the 
instrument or device and any connected equipment against damage. 

The safety notices are warnings for protection against loss of life (yours or service personnel) or for protection 
against damage to property and are highlighted in this manual by the terms and pictograms defined here. The 
terms used in this manual and marked on the instrument or device itself have the following significance: 

Danger: 

Indicates that death, severe personal injury, or substantial property damage will result if proper 

precautions are not taken. 

Warning: 

Indicates that death, severe personal injury, or substantial property damage can result if proper 

precautions are not taken. 

Caution: 

Indicates that minor personal injury or property damage can result if proper precautions are not taken. 

Note: 

Indicates important information about the product, its operation, or a part of the manual to which special 

attention is drawn. 

Attention: 

Hints in this documentation to special safety-related guidelines, which equate to the safety level of 

Caution and Note. 

 

 

This pictogram, is intended to alert the user to the presence of important operating and 
maintenance (servicing) instructions on the literature accompanying the instrument or 
device. 
 
This pictogram is used in relation to 

Danger

Warning

, and 

Caution

 notices. 

 

 

Summary of Contents for Digilance V

Page 1: ...HERAEUS Instruction and Operating Manual Temperature Measuring Unit Digilance V Document Version 1 01 Date of Issue 26 November 2018 Original instructions...

Page 2: ......

Page 3: ...Electro Nite This manual is copyrighted by Heraeus Electro Nite No part of this document may be reproduced transmitted transcribed stored in any retrieval system or translated into any language by any...

Page 4: ...Page 2 of 21 Digilance V 26 November 2018 File name Digilance V_1 01 Version 1 01...

Page 5: ...he Instrument 9 4 Standard Operation 10 4 1 First Use 10 4 2 Lance Installation 11 4 2 1 TC Wire Color Codes 11 4 3 Performing Measurements 12 4 3 1 Measurement Evaluation 12 4 4 Measurement History 1...

Page 6: ...rating personnel who have been trained to work with automation equipment instruments or electronic devices and are conversant with the content of the manual in as far as it is connected with the actua...

Page 7: ...Nite instruments placed on the market after 1 July 2006 do not contain materials prohibited according to the RoHS directive Affected parts and components are identified and adapted to the statutory re...

Page 8: ...ep the battery out of the reach of children Never use a battery that appears to have suffered abuse Battery must be charged in appropriate charger only Never use a modified or damaged charger Store ba...

Page 9: ...15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency...

Page 10: ...x which enables communication and data storage possibilities using Heraeus Electro Nite software The instrument also stores measurement results internally for downloading via the wireless interface 1...

Page 11: ...ies ensure that the conductive packing does not touch or short circuit the battery connections if necessary cover the connections with insulating tape or material 3 3 Packaging the instrument Since th...

Page 12: ...n Login o Instrument Info o Battery Info o Wireless Info optional Prior to using the instrument it is recommended to confirm the following instrument settings See Section Instrument Configuration Conf...

Page 13: ...ument Assembly according to the diagram Conductive Shielding of the Thermocouple Extension Cable may not extending into the instrument housing This could create a short circuit of the electronic compo...

Page 14: ...e Stop Difference 2 1 3 See Measurement Mode MULTI End Signal Duration 2 1 4 Controls the length of time that the Buzzer and Red Light will signal the end of the measurement Window 2 2 Temperature Res...

Page 15: ...ible to enter Heat Numbers from the Main Measurement Display Set Place1 8 3 2 1 8 Configure the List of Eight Measurement Place Names Alphanumeric 10 digits Display Place 3 2 9 If set to Yes it is pos...

Page 16: ...ed by pressing Charging Process Display Message LED Status Setup Charging Yellow Blinking Displayed when the Power Supply is initially connected to the device Charging Green Blinking Charge Level Indi...

Page 17: ...ion Awake Time 4 1 Determines how long the instrument will remain awake after activity Set the values to ALWAYS to manually power the instrument On and Off Motion Sensitivity 4 2 Controls the accelero...

Page 18: ...ITS90 1 3 L R Temperature Unit C F C F 1 4 Time 1 4 1 L R Time Format AM PM 24hr 24hr AM PM 1 4 2 Set Time 1 5 Date 1 5 1 L R Date Format DD MM YY MM DD YY DD MM YY MM DD YY 1 5 2 Set Date 2 Evaluatio...

Page 19: ...erial Number 6 Service 6 1 Device Status Hardware Status Screen 6 2 Load Standard Parameters Yes No No No 6 3 Reset All Parameters Yes No No No 6 4 Temperature Offset 5 0 C to 5 0 C 0 C 0 C 7 A Admini...

Page 20: ...tarting maintenance or installation make sure that you have sufficient protection against ESD Electronic devices can be destroyed by voltage and energy levels that are far below the level perceptible...

Page 21: ...ging limit 0 C The charge current is used to heat the pack charging will initiate when the temperature is above the minimum limit Battery too hot Battery is too hot for charging Battery Temperature is...

Page 22: ...s IPTS 48 IPTS 68 ITS 90 Thermocouple Accuracy Better than 1 C between 0 C and 50 C ambient temperature Display Resolution Configurable 1 or 0 1 Display Units C or F Data Storage 500 measurement resul...

Page 23: ...rial number Description UCS Part Number Battery Pack Replacement 31600257 Rubber Boot 31600258 Standard Housing Replacement 31600259 Wireless Housing Replacement 31600260 Antenna Assembly 31600261 The...

Reviews: