background image

OPERATION

 

Operate with a remote emitter 

Button operation: 

Button 1: switch to the next color program 

Button 2: turns the lamps ON/OFF. 

Button 3: turns ON/OFF switch A. 

Button 4: turns ON/OFF switch B.

 

 

MAINTENANCE 

FUSE: In case the lamps suddenly stop working, check incoming and outgoing voltage. If there 

is 220V going into the transformer and no 12V coming out, check the fuse and replace if 

necessary. This is an indication that there was a spike in voltage that damaged the fuse.   

 

SPARKING: In case of sparking and/or blackness around the connection terminals, scrape off 

all soot, reconnect cables and tighten as much as possible. 

 

REMOTE: In case the remote control stops working or is replaced, there is a small button on 

the remote module inside the transformer, press this button for 1 second, and then 

immediately press one of the 4 buttons on the remote to pair both devices. 

The battery inside the remote may require replacement. 

 

 

 

 

 

 

 

 

 

 

 

 

SAFETY WARNINGS 

The persons who are in charge of installation should have the required qualifications for this 

type of work. 

Avoid making contact with the electric voltage.   

Comply with the current standards regarding accident prevention.   

IEC 364-7-702 standards must be observed: WIRING IN BUILDINGS, SPECIAL WIRING, 

SWIMMING POOLS.   

Any maintenance works must be performed with the 220V incoming wire disconnected or 

switched off at the main supply.     

Do not handle any electrical components with wet feet. 

 

 

 

 

 

 

 

button 

Reviews: