User Manual Porty L
17
HENSEL-VISIT GmbH & Co. KG
Battery operation
ATTENTION!
Danger of explosion if the battery pack is handled improperly.
The battery flash generator must only be operated with genuine
Hensel lithium–ion batteries.
Batteries contain hazardous and caustic substances. Please note
the warning label on the battery.
The battery pack must not be opened or taken out of the
housing.
The battery pack must not be exposed to excessive heat like
sunshine, fire or such.
The battery pack must be protected from shock, vibration, and
moisture.
Battery pack removal and insertion
Â
Switch off the
Porty L
using the power switch
18
.
Â
Push down the unlocking device
23
on the battery pack and
pull the battery pack out of the unit’s front.
Â
Push the battery pack into the unit until you hear it lock into
place.
The charger Porty Lithium
ATTENTION!
The battery pack must only be charged with a genuine Hensel
charger Porty Lithium.
The micro chip controlled charger has an input voltage range
of 100-240 VAC. The charge time is 2 hours. After 45 minu-
tes, the battery has reached a charge level of 80% maximum
capacity.
The charge level is indicated on the charge indicator
E
.
Removal
Insertion