Positioning
C-Light lamp heads are equipped with a tilting head
8
.
The unit can be attached to a stand or a pantograph
using one of the two holes
a
. The head can be
swiveled round 360°. By tightening the knurl screw
b
the unit can be fixed. The safety screw must be
screwed into thread
c
. Wing nut
d
guarantees for tilting
up and down. To ensure smooth movement please oil
the thread if necessary. Above the tilting head an
umbrella holder
e
is integrated.
Fuses
Outlets, in the building:
minimum 10 A fuse outlets
Halogen lamp
The C-Light is usually protected by a fuse
2
, 6,3 A fast
(6,3 AF) for 230 V operation with a 1000 W halogen
lamp.
It is very important to check fuses before operation.
The required value depends on the mains voltage and
the type of the halogen lamp (
please refer to page 27,
Maintenance, Replacement of fuses, for looking up the
type
). A wrong fuse may cause a bursting of the
halogen modeling lamp.
Mains connection
Insert the plug of the provided power cable into the
mains connector
3
and then connect the cable to the
mains outlet.
Continuous light units must only be connected to
mains outlets with ground connection.