User manual // C-Light 1000
HENSEL-VISIT GmbH & Co. KG
23
5 Overview of controls
1
ON
Fan cooling ON/OFF
2
FUSE:
Fuse for halogen lamp
3
115V~/ 230V~; 50-60 Hz
Mains connector
4
MAIN SWITCH ON:
Halogen lamp ON/OFF
5
Fan
6
Handle
7
Reflector quick-change mechanism (see p. 25)
8
Hensel tilting head (see p. 24) with
8a 2 holes for stand mounting
8b knurl screw for stand fixing
8c thread for safety screw
8d wing nut for tilting
8e integrated umbrella holder
6 Starting up
Safety hints for operation with continuous light
Operation of halogen continuous light is only
allowed with correctly installed protection glass
dome due to the fact that halogen lamps in general
are at risk of bursting during operation. Make sure
that the protection glass dome is in place before
using the unit.
The protection glass dome is installed by putting it
carefully over the halogen lamp and fixing it with the
spring mechanism, which is mounted on the built-in
silver reflector. Avoid touching the halogen lamp with
the cover while mounting it. Handle the halogen lamp
with care.