Henny Penny OE-100 Technical Manual Download Page 14

2-8

Model OE-100

2-8.

FAN

The Henny Penny OE-100 has a fan in the circuit which operates only
when the power switch is in the COOK position. The fan helps keep
the control panel cool by pulling out heat from between the control
panel and frypot.

The replacement of a faulty fan is as follows:

To avoid electrical shock or property damage, move the
power switch to “OFF” and disconnect main circuit breaker,
or unplug cord at wall receptacle.

1. Remove control panel per Section 2-3.

593

2-7.

CONTACTORS
(Continued)

  

The Henny Penny OE-100 requires two switching contactors. Lo-
cated on the bottom is the primary contactor with the heat contactor
stacked to the top of the primary. When closed, the primary contactor
completes the heat circuit. It also supplies power to the heat contactor.

To avoid electrical shock or property damage, move the
power switch to “OFF” and disconnect main circuit breaker,
or unplug cord at wall receptacle.

1. Remove the control panel. Refer to Section 2-3.

2. Perform a check on the contactor as follows:

Test Points

Results

from 23 to 29

open circuit

from 24 to 28

open circuit

from 25 to 27

open circuit

from 30 to 34

open circuit

from 31 to 35

open circuit

from 32 to 36

open circuit

from 22 to 26

ohm reading 415

from 33 to 37

ohm reading 415

SHOCK HAZARD

SHOCK HAZARD

Summary of Contents for OE-100

Page 1: ...Henny Penny Open Fryer Electric Model OE 100 TECHNICAL MANUAL...

Page 2: ......

Page 3: ...the frypot without shortening 0 TO 3 YEARS During this time any frypot that fails due to manufacturing or workman ship issues will be replaced at no charge for parts labor or freight Henny Penny will...

Page 4: ...2 9 2 10 FUSES 2 10 2 11 DRAIN SWITCH 2 10 2 12 FILTER HEATER SWITCH 2 11 2 13 FILTER HEA TER 2 12 2 14 FILTERING SYSTEM 2 13 2 15 FILTER V ALVE 2 14 2 16 FILTER PUMPREPAIR 2 14 2 17 PUMP REMOV AL 2 1...

Page 5: ...WER position If display shows E4 heating circuits insulation and fan should be checked See Section 2 19 E5 Shorteningtoohot Unplugunit orturnoffcircuitbreakerto unit If display still shows E5 heating...

Page 6: ...witch Check drain switch per all other lights are Section 2 11 are extinguished Shortening will not Faulty contactor Check contactor per Section 2 7 heat but lights are illuminated Faulty temperature...

Page 7: ...edortheohmmetershouldreadzero 0 unlessother wise noted Whenthemanualreferstothecircuitbeingopen thecontinuitylight willnotilluminateortheohmmeterwillreadone 1 A continuity light cannot be used to chec...

Page 8: ...it breaker orunplug cord at receptacle 1 Draintheshorteningfromfrypot 2 Remove the decorative strips located on each side of the control panel by removing the screw located on the bottom of each decor...

Page 9: ...thehighlimitisnotdefective Reconnectthetwo electricalwires 1091 2 4 TEMPERATURE PROBE Continued 4 Unplug electrical wires from control panel board that are attached to temperature probe 5 Usinga1 2 w...

Page 10: ...ghten the capillary tube 8 Remove larger outside nut that threads into pot wall 9 Remove the two nuts that hold the high limit bracket from control panel area 10 Lift defective control from control pa...

Page 11: ...main circuit breaker or unplug cord at wall receptacle 1 Remove the control panel Refer to Section 2 3 2 Perform an ohm check on one element at a time with wires disconnectedfromelement Iftheresistanc...

Page 12: ...ithnew 0 rings 2 mountedon terminal ends and spreaders loosely mounted in the center of the heatingelements 9 Replacetheheatingelements terminalendfirst atapproximately 450 angle slippingtheterminalen...

Page 13: ...ts Results Primary Contactor It should from terminal 27 to 28 correspond to from terminal 28 to 29 the voltage from terminal 27 to 29 rating stated on the data plate If either contactor is defective i...

Page 14: ...itching contactors Lo cated on the bottom is the primary contactor with the heat contactor stacked to the top of the primary When closed the primary contactor completes the heat circuit It also suppli...

Page 15: ...lterpumpwill operate but the unit will not heat To avoid electrical shock or property damage move the power switch to OFF and disconnect main circuit breaker or unplug cord at wall receptacle 1 Remove...

Page 16: ...d at wall receptacle 1 Acontinuitycheckshouldbemadetodetermineifthedrain switch is defective Check between the two outer terminals with actuatoringrooveofthedrainvalveextensionrod Circuitshould be clo...

Page 17: ...connect main circuit breaker or unplug cord at wall receptacle 1 RemoveControlPanel butleavehingedonunit 2 Remove and label wires from the switch and check across from toptobottomforcontinuity Withthe...

Page 18: ...e move the powerswitch to OFF and disconnect main circuit breaker or unplug cord at wall receptacle 1 Open panel board and cut wires at the connectors which go to the heaters 2 Remove two screws that...

Page 19: ...hose is not connected to the fryer during normal opera tion 1 Attachthefilterrinsehosewithitsquickdisconnectfemalefitting totheotherhalfmalefittinginsidethedoor nexttothefiltervalve handle 2 To do thi...

Page 20: ...table wrench and remove the valve 7 Replace the valve and reassemble in reverse order 2 16 FILTER PUMP REPAIR Thetwomostcommoncausesforafryer sinabilitytopumpshortening isthatthepumpiscloggedwithbread...

Page 21: ...emainonthemotorshaft orifleaking should be replaced at this time 3 To replace the pump remove the four allen screws front plate rotor and rollers from pump see Section 2 18 Place the pump onto shaft a...

Page 22: ...tor and pump assembly 2 19 COOLING FAN MAINTENANCE The cooling fan on the OE 100A open fryer reduces the amount of heat behind the panel and if the heat does become excessive E 4 will show on the disp...

Page 23: ...it needs replaced if fan is operating con tinue onto step 3 To avoid electrical shock or property damage move the power switch to OFF and disconnect main circuit breaker or unplug cord at wall recepta...

Page 24: ...2 18 Model OE 100 994...

Page 25: ...2 19 Model OE 100 1197...

Page 26: ...2 20 Model OE 100 1197...

Page 27: ...2 21 Model OE 100 694...

Page 28: ...2 22 Model OE 100 1294...

Page 29: ...without shortening 0 TO 3 YEARS During this time any frypot that fails due to manufacturing or workman ship issues will be replaced at no charge for parts labor or freight Henny Penny will either ins...

Page 30: ......

Page 31: ...r parts order 3 5 DELIVERY Commonly replaced items are stocked by your distributor and will be sent out when your order is received Other parts will be ordered by your distributor from Hermy Penny Cor...

Page 32: ...3 2 Model OE 100 Figure 3 1 OE 100 Frypot Drain Valve 412...

Page 33: ...SC01 059 Screw Machine 1 4 20X1 2 2 8 30173 Grip Drain Rod 1 9 30082 Rod DrainValve 1 10 30085 Latch Safety 1 11 NS02 005 Nut 6 32 2 12 18227 Switch DrainValve 1 13 30083 Cover Drain Switch 1 14 SC02...

Page 34: ...3 4 Model OE 100 Figure 3 2 OE 100 Heating Elements 896...

Page 35: ...Heater Brass 5 8 6 5 WA01 007 Flat Washer 10 Brass Nickel Plate 6 6 LW01 008 Lockwasher Splitring 10 6 7 NS01 014 Nut 10 32 Hex Nickel Plate 6 8 40315 HiLimitClamp Back 1 9 40317 HiLimitClamp Front 1...

Page 36: ...3 6 Model OE 100 Figure 3 3 OE 100 Insulation 593...

Page 37: ...69 Insulation End 2 5 30056 InsulationSupportW A 2 6 SC02 018 Screw Thread Forming 8AB 7 30068 Seal 1 8 30070 Bracket Seal 2 9 30069 Plate Seal 4 10 30071 Bracket Seal 2 11 30067 Seal 1 12 30134 Insul...

Page 38: ...3 8 Model OE 100 Figure 3 4 OE 100 Fan Contactors and High Limit Assembly 905...

Page 39: ...uit breakers 30324 Contactor w Set Screws 2 208 240 Volt fryers before June July 1991 w o circuit breakers 4 NS02 005 Nut 6 32 Keps 4 5 16688 Fan 1 6 SC03 005 Screw SelfDrilling 8 2 7 44227 Shield Spl...

Page 40: ...3 10 Model OE 100 Figure 3 5 OE 100 Frame Assembly 593...

Page 41: ...13 SC01 046 Screw Machine 8 32 x 1 2 14 30064 PanelEnd Right 1 15 30084 Bracket Safety 1 16 30001 Latch Spring 1 17 30002 Hinge Slip Joint Male 1 18 SC02 018 Screw Thread Forming 8 19 30066 Plate Clos...

Page 42: ...3 12 Model OE 100 Figure 3 6 Control Panel Assembly 1209...

Page 43: ...006 Nut 10 24 Hex Keps 6 5 61755 Card Menu 2 6 30357 Label Warning 1 7 40500 Assembly Alarm CPU 1 Old Syle w attached PCB 1 7 ME70 001 Buzzer Piezo New Syle w o PCB 1 8 28979 Transformer 1 9 30261 Sw...

Page 44: ...3 14 Model OE 100 Figure 3 7 OE 100 Lower Filter Plumbing Components 795...

Page 45: ...Connector Male Elbow 1 6 16808 Fitting Sleeve 1 7 16809 Nut Fitting 1 8 45721 Tubing StainlessSteel 1 9 17432 use69289 Fitting UnionHandle 1 10 17431 use69289 Fitting FemaleUnion 1 11 17430 use69289 F...

Page 46: ...3 16 Model OE 100 Figure 3 8 OE 100 Filter Assembly 593...

Page 47: ...Y 3 8 OE 100 FILTERASSEMBLY 1 17510 use14671 FilterScreenAssembly 1 2 65211 Crumb Catcher 1 3 17502 use14671 Top Screen 1 4 17503 use14671 Bottom Screen 1 5 17505 FilterClips 2 6 12101 FilterEnvelope...

Page 48: ...3 18 Model OE 100 Figure 3 9 OE 100 Supersorb Filter 1093...

Page 49: ...3 9 OE 100 SUPERSORB FILTER 1 17430 use69289 Union FemaleFitting 1 2 37855 FilterPanAssembly 1 3 37135 FilterClampRingAssembly 1 4 36596 Handle FilterLock 4 5 NS03 023 Nut 1 4 20Acorn Cap 4 6 30944 S...

Page 50: ...3 20 Model OE 100 Figure 3 10 Upper Filter Plumbing Components 896...

Page 51: ...G S S 1 7 FP02 001 NIPPLE Close 1 8 17306 TEE Pipe 1 9 FP02 015 PLUG Pipe I 10 03001 HOSEASSEMBLY Filter Rinse Optional 1 11 30228 NIPPLE Pipe 1 12 17334 FITTING Rinse Hose Disconnect Male 1 13 03003...

Reviews: