Model MP-941/942/943/944
2-2. UNPACKING (Continued)
4. Open drawers and remove the packing or literature
that is inside.
5. Pull off any protective covering from the exterior of
the
cabinet.
6. Your multipurpose holding cabinet is now ready
for location and setup.
2-3. ELECTRICAL
The multipurpose holding cabinets are available from
the factory as 120 VAC for domestic use, or 230 VAC
for international use. The units are single phase and
require a grounded (earthed) receptacle with a separate
electrical line protected by a fuse or circuit breaker of
the proper rating.
The electrical plugs for the 230 volt units must be
supplied by the distributor and have the proper
DATA TABLE:
grounding (earthing).
To avoid electrical shock, the cabinet must be
adequately and safely grounded (earthed)
according to local electrical codes.
(FOR EQUIPMENT WITH CE MARK ONLY!)
To prevent electric shock hazard this appliance
must be bonded to other appliances or touchable
metal surfaces in close proximity to this
appliance with an equipotential bonding
conductor. This appliance is equipped with an
equipotential lug for this purpose. The
equipotential lug is marked with the following
symbol
After the multipurpose holding cabinet has been set into
position and leveled, run a bead of silicone rubber
(silicone or equivalent sealant must be a NSF listed
material) around the perimeter of the unit sealing it to
the surface. You are now ready to make the electrical
connections to the unit.
2-2
208
Model
Number
Volts
Phase
Watts
Amps
MP-941 120 1 475 3
MP-942 120 1 950 6
MP-943 120 1 1425 9
MP-944 120 1 1900 12
MP-941 230 1 475 2
MP-942 230 1 950 4
MP-943 230 1 1425 6
MP-944 230 1 1900 8