3-7. OPERATING CONTROLS
Output Test (Continued)
900 and 903 CDT
(if applicable)
6. Press the 5 timer button (under “Htr”) to turn heat and heat LED
(Continued)
on and off.
7. Press the PROGRAM button to move to the next step, or press
and hold the PROGRAM button to exit programming.
Temperature Calibration
1. Press and hold the PROGRAM button for 4 seconds.
2. “Setup” and “Tech” is displayed.
3. Press a timer button under the word “Tech”.
Ex:
Tech
Press either 4 or 5.
4 5
4. Enter access code 1, 1, 2, 2, 1, 1, 2, 2.
5. “outP test Htr” is displayed.
6. Press the PROGRAM button 3 times until “CAL OFS Hi Probe
185” is displayed.
7. Press and hold number 1 timer (under “CAL”), while pressing the
INCREASE and DECREASE buttons and set the display to
match the actual cabinet temperature.
8. Press the PROGRAM button to move to the next step or press
and hold the PROGRAM button to exit programming.
401
3-11