Time Mode:
1.
Press the footswitch to activate the system.
2.
The dispense timer will be activated and start to dispense with preset time.
3.
After the dispensing timer has reached the preset dispensing time, the dispensing
will be stopped.
Continuous Mode:
1.
Press the footswitch to activate the system
2.
The system will start to dispense, and the dispensing timer will start to count the
dispensing time.
3.
Once the footswitch is released, the dispensing will stop.
Additional Features:
EMPTY Signal:
If the reservoir is empty the contact of the level sensor opens. Three different types of
Empty Signal can be selected.
Mode 1: Digital Only
Mode 2: D Lamp
Mode 3: D System Stop
READY Signal:
If the dispensing cycle is finished and unit is not dispensing, a contact is closed and a
<READY> signal is communicated. The ready signal only indicates that the dispensing
is either ON (busy) or OFF (ready). This signal is independent of any other conditions.
Both EMPTY and READY signals are available as dry contacts at the XS1 start interface
for optional connection to an external PLC. Any external sources need to be
programmed to suit end user requirements.
In Mode 3, the ready signal will be communicated even though an Empty signal may be
communicated, however, the system will not dispense.
Caution!
Pay attention if cyanoacrylate is dispensed
–
Air in the feed line results in curing of the
product!