background image

1   Please observe the following 

1.4   For Your Safety 

   

  For safe and successful operation of the unit, read these instructions completely.  If 

the instructions are not observed, the manufacturer can assume no responsibility. 

  Do not expose the connecting cable to heat, oil, or sharp edges. 

  Make sure the Unit stands stable and secure. 

  Use only original equipment replacement parts. 

  Always disconnect the power supply before servicing the unit. 

  Observe general safety regulations for the handling of chemicals such as Loctite

®

 

adhesives and sealants.  Observe the manufacturer’s instructions as stated in the Safety 
Data Sheet. 

     While under warranty, the unit may be repaired only by an authorized Loctite 

service representative.  

 

 

 

 

Warning! 

 
It is the responsibility of the user to ensure that all devices being driven by the LED Spot Controller 
are set-up in a safe manner. 
 
The manufacturer is in no way responsible for injuries or damage to persons or property resulting 
from devices being driven by the LED Spot Controller. 
 
For safe and successful operation of the unit, read these instructions completely. If the instructions 
are not observed, the manufacturer can assume no responsibility. 
 
Removing, bypassing or putting out of operation any of the safety devices can result in radiation 
damage to persons and damage to the unit and is therefore prohibited! 
 
Do not look directly at LED-UV light, or at LED-UV light reflected in a mirror or other reflective 
surface. Doing so could cause eye damage. 
 
Install the LED head in a way that humans are not exposed to LED-UV light. 
 
Exposure could injure the skin or cause other injury. 
 
If there is a risk of the LED-UV light being exposed to UV reflective light, place the product inside a 
cover with proper reflectance and heat characteristics to block that reflected light. 
 
When operating the controller, set up the system so that the path of the LED-UV light is not at eye 
level. 
 
It is strongly recommended to place a protective barrier around the product so that people cannot 
approach it while it is operating. 
 
Wear protective UV glasses and other protective clothing during operation. 
 
Never operate this product in a manner not described in this manual. Doing so risks exposure to 
LED UV light. 
 
Damage to the power cord or the housing can result in contact with live electrical parts. Check the 
power cord and the unit before each use. If the power cord or the unit is damaged, do not operate! 
Replace a damaged power cord with a new one. 
 
The unit may be opened and repaired only by authorized service personal. 
 

 

 

Summary of Contents for 2804959

Page 1: ...EQ CL42 LED Flood Chamber IDH 2804959 Operating Manual ...

Page 2: ...neral Description 5 3 Technical Data 7 4 Installation 7 4 1 Environmental and Operating Conditions 7 4 2 Assembly of the LED Flood Arrays 7 5 Operation 8 5 1 Start of Radiation Cycle 8 5 2 Door Safety System 8 5 3 Shutdown 8 5 4 Returning to Operation 8 6 Service and Maintenance 8 7 Troubleshooting 9 8 Spare Parts and Accessoires 9 9 10 Declaration of Conformity 20 Declaration of Conformity 10 Equ...

Page 3: ...mmendations for better handling or adjustment of the unit during operation as well as for service activities The numbers printed in bold in the text refer to the corresponding position numbers in the illustration on page 6 7 1 2 Items Supplied 1 EQ CL42 LED Flood Chamber Order Code No 2804959 consists of 1 Chamber 2804959 1 Connection Cable Chamber Controller XS9 1 Adapter plate for 2 LED Flood Ar...

Page 4: ...ibility Removing bypassing or putting out of operation any of the safety devices can result in radiation damage to persons and damage to the unit and is therefore prohibited Do not look directly at LED UV light or at LED UV light reflected in a mirror or other reflective surface Doing so could cause eye damage Install the LED head in a way that humans are not exposed to LED UV light Exposure could...

Page 5: ...o make the stray light useable for the curing process The start signal for the radiation cycle can be actuated with the closing of the chamber door The window in the chamber door consists of special antistatic Polycarbonate to avoid damages of sensitive electronically parts The yellow tanning of the window pane gives protection to the user against damages to the eyes due to blue light radiation wi...

Page 6: ...te 4 Level rail A higher position of the substrate to cure provides higher intensity and for this a faster curing 5 Chamber door with window made out of antistatic yellow tanned Polycarbonate Note Requires Cl42 LED Flood cure system sold separately 2 3 5 4 ...

Page 7: ...ith the delivered knurled screws with the curt outs aligned Following this remove at the left LED flood array the middle screw on the left side of the housing and at the right LED flood array the middle screw at the right side of the housing to fix the arrays to the adapter For the fixing of the flood arrays to the adapter please use the delivered M3 hexagon socket screws 4 3 Connection of the LED...

Page 8: ...nd a warning beep occurs This error will be displayed if the cure cycle is interrupted by the user The radiation cycle can be start again until the warning message is cleared 5 3 Shutdown Remove unit from power supply 5 4 Returning to Operation Check installation regarding section 4 Connect unit to power supply 6 Service and Maintenance The polycarbonate window of the door may just be cleaned with...

Page 9: ... closing of the chamber door Connection cable XS9 to Chamber is disconnected or defective Door switch faulty Check the cables and reconnect or change the cable if necessary Henkel Service 8 Spare Parts and Accessoires Pos Description Type No Order No 1 Connection Cable XS9 N A N A ...

Page 10: ...9 Declaration of Conformity ...

Page 11: ...ding where products parts or attachments for use in connection with the Products are available from Henkel the use of products parts or attachments which are not manufactured by Henkel no claim shall be allowed No Products shall be returned to Henkel for any reason without prior written approval from Henkel Products shall be returned freight prepaid in accordance with instructions from Henkel NO W...

Page 12: ...Haw Par Technocentre SINGAPORE 149598 Henkel China Company Ltd No 928 Zhang Heng Road Zhangjiang Hi Tech Park Pudong Shanghai China 201203 Henkel Loctite Korea 8F Mapo Tower 418 Mapo dong Mapo gu Seoul 121 734 KOREA Henkel Japan Ltd 27 7 Shin Isogo cho Isogo ku Yokohama 235 0017 JAPAN Henkel AG Co KGaA Henkelstraße 67 40191 Düsseldorf Deutchland www equipment loctite com and designate trademarks o...

Reviews:

Related manuals for 2804959