background image

 

1   Please observe the following 

 

 

For safe and successful operation of the unit, read these instructions completely. The 
manufacturer cannot be held responsible for damage or injury of any kind because of 
misuse or improper application or because of failure to observe safety instructions or 
warnings. 

Be sure to retain this manual for future reference. 

1.1   Emphasized Sections 

 

 

 

Warning!

 

Refers to safety regulations and requires safety measures that protect the operator or 
other persons from injury or danger to life. 

 

 

 

 

 

 

Caution!

 

Emphasizes what must be done or avoided so that the unit or other property 
is not damaged. 

 

 

 

 

 

 

Notice

 

Gives recommendations for better handling or adjustment of the unit during operation as 
well as for service activities. 

   

The numbers printed in bold in the text refer to the corresponding position numbers in the 
illustration on page 

6

-

7

1.2   Items Supplied 

   

1 EQ CL42 LED Flood Chamber, Order Code No. 2804959, 
consists of: 
1 Chamber, 2804959 
1 Connection Cable Chamber 

– Controller (XS9) 

1 Adapter plate for 2 LED Flood Arrays 
1 Adapter plate for 1. LED Flood Array 
1 Work piece holder plate 
1 Operating Manual 

 

 

 

Notice

 

As a result of technical development, the illustrations and descriptions in this instruction 
manual can deviate in detail from the actual unit delivered. 

1.3   Field of Application (Intended Usage)

 

   

The new LED Flood Chamber has been 
developed for the use with max 2 of Cl42 
LED Flood Systems. 
The picture shows the set up with 1 flood 
system.  

 

 

 

 

Summary of Contents for 2804959

Page 1: ...EQ CL42 LED Flood Chamber IDH 2804959 Operating Manual ...

Page 2: ...neral Description 5 3 Technical Data 7 4 Installation 7 4 1 Environmental and Operating Conditions 7 4 2 Assembly of the LED Flood Arrays 7 5 Operation 8 5 1 Start of Radiation Cycle 8 5 2 Door Safety System 8 5 3 Shutdown 8 5 4 Returning to Operation 8 6 Service and Maintenance 8 7 Troubleshooting 9 8 Spare Parts and Accessoires 9 9 10 Declaration of Conformity 20 Declaration of Conformity 10 Equ...

Page 3: ...mmendations for better handling or adjustment of the unit during operation as well as for service activities The numbers printed in bold in the text refer to the corresponding position numbers in the illustration on page 6 7 1 2 Items Supplied 1 EQ CL42 LED Flood Chamber Order Code No 2804959 consists of 1 Chamber 2804959 1 Connection Cable Chamber Controller XS9 1 Adapter plate for 2 LED Flood Ar...

Page 4: ...ibility Removing bypassing or putting out of operation any of the safety devices can result in radiation damage to persons and damage to the unit and is therefore prohibited Do not look directly at LED UV light or at LED UV light reflected in a mirror or other reflective surface Doing so could cause eye damage Install the LED head in a way that humans are not exposed to LED UV light Exposure could...

Page 5: ...o make the stray light useable for the curing process The start signal for the radiation cycle can be actuated with the closing of the chamber door The window in the chamber door consists of special antistatic Polycarbonate to avoid damages of sensitive electronically parts The yellow tanning of the window pane gives protection to the user against damages to the eyes due to blue light radiation wi...

Page 6: ...te 4 Level rail A higher position of the substrate to cure provides higher intensity and for this a faster curing 5 Chamber door with window made out of antistatic yellow tanned Polycarbonate Note Requires Cl42 LED Flood cure system sold separately 2 3 5 4 ...

Page 7: ...ith the delivered knurled screws with the curt outs aligned Following this remove at the left LED flood array the middle screw on the left side of the housing and at the right LED flood array the middle screw at the right side of the housing to fix the arrays to the adapter For the fixing of the flood arrays to the adapter please use the delivered M3 hexagon socket screws 4 3 Connection of the LED...

Page 8: ...nd a warning beep occurs This error will be displayed if the cure cycle is interrupted by the user The radiation cycle can be start again until the warning message is cleared 5 3 Shutdown Remove unit from power supply 5 4 Returning to Operation Check installation regarding section 4 Connect unit to power supply 6 Service and Maintenance The polycarbonate window of the door may just be cleaned with...

Page 9: ... closing of the chamber door Connection cable XS9 to Chamber is disconnected or defective Door switch faulty Check the cables and reconnect or change the cable if necessary Henkel Service 8 Spare Parts and Accessoires Pos Description Type No Order No 1 Connection Cable XS9 N A N A ...

Page 10: ...9 Declaration of Conformity ...

Page 11: ...ding where products parts or attachments for use in connection with the Products are available from Henkel the use of products parts or attachments which are not manufactured by Henkel no claim shall be allowed No Products shall be returned to Henkel for any reason without prior written approval from Henkel Products shall be returned freight prepaid in accordance with instructions from Henkel NO W...

Page 12: ...Haw Par Technocentre SINGAPORE 149598 Henkel China Company Ltd No 928 Zhang Heng Road Zhangjiang Hi Tech Park Pudong Shanghai China 201203 Henkel Loctite Korea 8F Mapo Tower 418 Mapo dong Mapo gu Seoul 121 734 KOREA Henkel Japan Ltd 27 7 Shin Isogo cho Isogo ku Yokohama 235 0017 JAPAN Henkel AG Co KGaA Henkelstraße 67 40191 Düsseldorf Deutchland www equipment loctite com and designate trademarks o...

Reviews:

Related manuals for 2804959