10
5
Operation
5.1 Indicator Light – color and function
Indicator lights table below provides the list of which level control units have the
indicator light. The list is in order of how the indicator lights appear on the level
control panel. Top of the list is top of the panel; bottom of the list is bottom of the
panel. List also shows the which level control units have the indicator light. Only
master level control units have the Master Air Level pressure switch and indicator
light. Standard level control units do not have this feature.
Indicator Label
Indicator
Color
Indicator ON when
1 PT
Level
2 PT
Level
3 PT
Level
4 PT
Level
Mater Air Low
Red
no or low air out of
regulator
X*
X*
X*
X*
High Level
Alarm
Red
high level condition
X
X
Operating Level
Green
at operating level
X
X
X
X
Control Point
Amber
filling
X
X
X
X
Low Level Alarm
Red
low level condition
X
X
X
Pump Shut
Down
Red
pump (or heater)
shut down – server
low level condition
X
* only Master Level Control units have a Master Air Low indicator and internal
pressure switch. Standard Level Controls do not have the Master Air Low
indicator.
Two-point level control unit can be reconfigured as a special for operations
requiring a “Control Point” and “High Level Alarm”. Inquire about this option
with your Henkel representative.
5.2 Adjusting Master Air Pressure Switch
The master air pressure switch changes state based on the set and reset point
adjustment. The pressure switch is adjustable from 8 to 25 psig. The set and reset
points have a fixed difference of 1.8 psig.
Summary of Contents for 2250048 REV
Page 1: ...E CO Level Control 120 VAC One Two Three and Four Points Operating Manual ...
Page 2: ......
Page 25: ...21 9 3 2251340 REV E CO Level MSTR 2 PT electrical ...
Page 26: ...22 9 4 2251339 REV E CO Level STD 2 PT electrical ...
Page 27: ...23 9 5 8907225 Master Level Control Three Point electrical ...
Page 28: ...24 9 6 8907224 Standard Level Control Three Point electrical ...
Page 29: ...25 9 7 8907227 Master Level Control Four Point electrical ...
Page 30: ...26 9 8 8907226 Standard Level Control Four Point electrical ...
Page 31: ...27 9 9 Level Control Standard and Master Installation Drawing 8907228 ...