17
6 Care, Cleaning and Maintenance
6.2.2 Assembly
•
Slightly grease threads and neck of
actuator
2
.
•
Insert new diaphragm
3
in shut off
valve
4
.
•
Screw actuator
2
onto shut off valve
4
and tighten securely by hand, then by
using wrench size 17 turn max. 180° to
fix them correctly and get dispensing
valve tight in accordance with the data
of the sticker (max.17 Nm).
•
Connect feedline and pneumatic tube and slip on dispensing nozzle.
ACHTUNG:
Vor Inbetriebnahme
Ventilober- und
Unterteil (SW 17 mm)
handfest nachziehen
(max 17 Nm).
NOTE:
Hand-tighten valve
top and bottom
(wrench opening
17 mm) prior to first
use (17 Nm max.).