eXtendo
®
Thermal Printer Family
HENGSTLER
Part No. D 684 124
Mod. No. 4 080812 LEV
page 38 of 38
13.3.2. EN55022 – Emissions
The eXtendo
®
family of thermal printers are class “B” appliances, and comply to
applicable Class “B” standards, when installed in a properly grounded housing with
appropriate conductive shielding.
When operating the printer from a DC building power supply, or when the DC power
cable exceeds 3 meters in length, appropriate EMI filters must be used.
13.3.3. EN55024 – Electromagnetic Susceptibility
Electrostatic discharges and burst effects may cause short printing interruptions, but
the automatic recovery function of the printer will restore it to its original state.
Additional action regarding lightning and overvoltage protection will be needed if
cables and wires are installed outside of a building.
However, this standard can be met only if original units, components, and cables are
used and the installation instructions are respected and followed completely.
External interference caused by ESD or EMI can temporarily cause corrupted printing
or data loss.
13.4. Printer Drawings
Please refer to the appropriate drawing listed in section 1.1 of this document for dimensions
and complete mounting hole position information.