DEEP-FREEZER AND STORAGE RANGE
page 14 out of 37
3.1.5
Assembly of the back panel
Remove film of protection of the back panel
Attach the back panels (11) to the bottom (10) to get started
Attach, lock and verify the good alignment of the panels with the
ground (
Fig.A
)
Fig.A : Vérifier
l’alignement
3.1.6
Frontage assembly
Remove the protection film from the frontage panels.
Implementthe frontage panel (13) ensuring that it is positioned in the
basement on the ground
Attach, lock and verify the alignment of the frontage with the ground
3.1.7
Assembly of the first side (left side of the equipment)
Please follow these steps carefully to get a good
alignment during assembly of the panel:
Remove the protective film from the panel
Place a bead of silicone moldings on the frontage, the ground and
the bottom
Lock the hooks (13-1) and (13-2) of the frontage, verifying the
alignment of the panel and the front part
Lock the hooks (11-1) and (11-2) of the back, verifying the alignment
of the panel and the front part
Lock both hooks of the ground with the side panel
The two hooks left (13-3) and (11-3) must be locked after the
assembly of the platform.
Fig B : Face d
’alignement
11
10