![Hendi 979983 User Manual Download Page 7](http://html1.mh-extra.com/html/hendi/979983/979983_user-manual_2123570007.webp)
7
EN
3D
3E
3G
mount ring
rubber gasket
support
ring sink
fl ange
top of sink fl ange
open area,
no obstruction
mount ring should be
free to move up & down
sink
fi ber
bottom
bead of
cushion
mount
cushion
mount
bottom
bead
groove
support
ring
bottom “lip“
of sink fl ange
4. ELECTRICAL CONNECTIONS
A. Connect disposer to appropriate household current only.
DANGER: IMPROPER CONNECTION OF THE EQUIP-
MENT-GROUNDING CONDUCTOR CAN RESULT
IN A RISK OF ELECTRIC SHOCK. CHECK WITH
A QUALIFIED ELECTRICIAN OR SERVICEMAN
IF YOU ARE IN DOUBT AS TO WHETHER THE
APPLIANCE IS PROPERLY GROUNDED. DO NOT
MODIFY THE PLUG PROVIDED WITH THE APPLIANCE
IF IT WILL NOT FIT THE OUTLET. HAVE A PROPER
OUTLET INSTALLED BY A QUALIFIED ELECTRICIAN.
4.1 GROUNDING INSTRUCTIONS
FOR WASTE DISPOSERS EQUIPPED WITH A GROUNDED PLUG-IN POWER CORD.
B. This appliance must be grounded. In the event
of a malfunction or breakdown, grounding pro-
vides a path of least resistance for electric cur-
rent to reduce the risk of electric shock. This
appliance is equipped with a cord having an
equipment-grounding conductor and a ground-
ing plug. The plug must be plugged into an
appropriate outlet that is properly installed and
grounded in accordance with all local codes
and ordinances. If the supply cord is damaged
it must be replaced by the manufacturer, its ser-
vice agent or similarly qualifi ed person in order
to avoid a hazard.