3.4 Connection to the water supply
ATTENTION:
The connection with the water supply
should be made according to the current safety
standards.
The dishwasher may be connected only to a cold
water supply.* (In case you want to connect it to a
hot water supply, please contact our company)
• The water supply hose should have a flap valve
(non-return valve) according to DIN 1988.
• The water supply hose/pipe should be rinsed be-
fore the appliance’s connection.
• The water supply hose/pipe should have a mini-
mum internal diameter of
• 16 mm and the connection with the hose should
be 3/4 inch.
• All hose collars should be adjusted in a fixed po-
sition before the appliance is put into operation.
• The dishwasher can be only connected to a
well-functioning softener
ATTENTION:
The water pressure must be between 2
and 5 bar.
3.4.1 Drainage connection
The outflow is accomplished through gravity force
(natural flow). The outlet hose should be connected
either directly to the main drainage - where a pipet-
te for odours is anticipated, or water runs directly to
a drainage well in the ground, which has a pipette
for odours.
ATTENTION:
The outlet hose should not be placed
higher than a level (as given for each appliance’s
type) from the lower side of the dishwasher’s
dispenser.
3.5 Electrical Network connection
ATTENTION:
All electrical work must be carried out
by a suitably qualified and competent person.
The dishwasher operates under specific voltage de-
pending on the type of the dishwasher.
You should supply the power, depending on the ap-
pliance’s power reception (the electrical connection
should be made by authorized electricians). Specifi-
cations should be met according to the correspon-
ding parts of DIN, VDE, D100, the EVU connection
terms, the relevant ZH 1/37, chapter 7.2 - as well as
the current specifications for accident prevention.
Respectively, the appliance must be connected to a
direct power supply electrical installation through
an HO7 RN-F cable with load relief of the appliance.
3.5.1 Protective duct connection and voltage compensation
The electrical safety of this appliance is ensured
only if the protective duct has been connected and
checked properly. The corresponding specifications
should be met at this point (see paragraph 1.5).
In addition, the appliance should include a voltage
compensation system.
For this reason, the backside of the appliance has a
screw with the indication “voltage compensation”.
Following the electrical connection, the action of
the protective duct, the voltage compensation and
the insulation value should be checked according to
the existing provisions of DIN VDE.
Operation of the drain pump.
To start the pump, do the following:
1. Exclusion
2. Pull out the overflow valve
3. Close the door
4. Knife “start”
After pressing the “start” button for 120 seconds, I
will stop automatically, if you need a further water
drain, repeat the cycle.