Screw the bolts firmly in place
and move the plug wire into the
fuel igniter. NOTE! Do not tighten
the thermocouple very firmly. The
appliance will be damaged and
unable to function if you tighten it
too firmly.
9
Place the rating label (natural gas) over the existing rat-
ing label.
Remove the hose and pressure
regulator. The gallery is equipped
with a 1⁄4 connection. Let this
connection be done by a recog-
nized installer.
Cleaning and maintenance
• Let the appliance cool down before cleaning
• Beware: Never immerse the appliance in water
or any other liquid!
• Clean the outside of the appliance with a damp
cloth (water with mild detergent).
• Clean the ventilation slots (if applicable) with a
vacuum cleaner.
• Keep inside after use.
• Let specialised personnel clean at least once a
year the burner.
• Never use a high pressure cleaner.
Troubleshooting
If the appliance does not function properly, please check the below table for the solution.
If you are unable to solve the problem, please contact the supplier / service provider.
Defects
Possible causes
Burner won’t ignite
Ignition malfunction
Thermocouple malfunction
Dirty spark plug
Gas hose blocked
Injector blocked
Burner will not ignite fully
Gas hose blocked
Gas valve not completely open
Injector blocked
Gas valve malfunction
Summary of Contents for 147108
Page 51: ...51 GR Hendi 10...
Page 52: ...52 GR 30 cm...
Page 53: ...53 GR 1 2 3 4 5 10 10 Hokker 147108 147184 DE PL LU AT CH IT HU GB IE GR BE FR 1 7...
Page 54: ...54 GR 2 3 4 120 190...
Page 55: ...55 GR 5 6 7...
Page 56: ...56 GR 8 9 1 4...
Page 57: ...57 GR 3 4 213 0 998989 10 info pks hendi com...
Page 65: ...65...