Lockout codes
Blinks Fault
Cause
1
Micro controller failure
Micro controller is continually rebooting.
2
Mains under voltage
The mains voltage has dropped below 180 volts AC running.
NOTE: If this fault is active, the controller will reboot after
voltage comes above 209 volts AC for at least 6 seconds.
3
Temperature
Over temperature (100°C).
Under temperature (-20°C).
4
Over current trip
Over current protection has tripped.
5
Mains over voltage
The mains voltage has risen above 269 volts AC.
6
Output shaft seized
Motor failed to start.
Motor was stopped.
7
Self check
One or more of the self-tests failed either at start-up
or while running.
8
Motor fault
One or more of the phases have become disconnected.
9
Other fault
Any fault not covered by the other codes. Presently no faults
should trigger this.
10
EEPROM load failure
Checksum failed while loading EEPROM to memory.
Removal of the Pump from Pipework
Should it be necessary to remove the pump, follow these
instructions:
1. Switch off the power and remove the plug from the
power source.
2. Close the water valves on the pool return and the pump
inlet pipework.
3. Remove the discharge & suction barrel unions taking
care not to lose the o-rings.
4. Move the pipework with the barrel unions attached
until the pump can be pulled clear.
NOTE: When making any
enquiries about your Henden 3
Speed Pump, be certain to quote
the model number from the
nameplate located on the motor.
NOTE: If the pump is wired into a time
clock or another automatic control, the
wiring should be removed by a qualified
technician.
Water Quality
Maintaining balanced water chemistry is important to
the life of your pool pump. This pump is designed to be
used with pool & spa water, balanced in accordance with
Langlier Saturation Index, with a pH level of between 7.2
and 7.8 and is regularly treated with a chlorine sanitising
agent with the level not exceeding 3.0 parts per million of
free chlorine.
Please consult your local Reece Irrigation & Pools branch
regularly to have your water tested.