2. PIPE CONNECTION

A barrel union is provided for connecting to the piping 
from the pool. The barrel unions are designed to accept 
40mm PVC on the ID or a 50mm PVC fitting on the OD.

When plumbing the discharge pipe, ensure that the 
pipework does not interfere with the touchpad’s 
protective cover, which needs to fully open and close.

Ensure pipework from 
discharge does not interfere 
with protective cover.

Barrel unions need to be hand 
tightened. No sealant, glues or 
silicones are required.

The use of any pipe smaller than those specified above is 
not recommended. Suction piping should be free from all 
air leaks and any humps and hollows which cause suction 
difficulties.
The discharge piping from the pump outlet should be 
connected to the inlet connection on the swimming pool 
filter (usually at the filter control valve).

ELECTRICAL DATA

Model

H83SP

RPM

Eco Flow Speed – 1400

Mid Flow Speed – 2400

High Flow Speed – 2850

Enclosure Class (IP)

24

Insulation Class

Class B 130 Insulation

Voltage (V)

240 AC

Supply Frequency (Hz)

50

Run current (A)

6.3

Motor Input Power (W / hp)

Eco Flow -  168W / 0.23hp

Mid Flow – 679W / 0.91hp

Hi Flow – 1,125W / 1.51hp

Motor Output Power (W / hp)

Eco Flow -  127W / 0.17hp

Mid Flow – 521W / 0.70hp

Hi Flow – 853W / 1.14hp

Operating Limits:

Max Water temperature

50°C

Max Ambient temperature

55°C

Dimensions:

Model

A

B

C

D

E

Mounting 

Holes

Diameter

Inlet

PVC

Outlet

PVC

Net

Weight 

(kg)

H83SP 645 330 250 305 246

10

*40/50 *40/50 15.9

A

B

C

D

E

*Suction and delivery accept 40mm PVC pipe on the I.D. and 50mm fitting on the O.D.

Summary of Contents for H83SP

Page 1: ...nowledgeable in swimming pool plumbing requirements following the installation instructions provided in this manual Henden 8 3 Speed Pump H83SP A joint government and industry program Henden Pump Mode...

Page 2: ......

Page 3: ...N 5 OWNERS MANUAL 3 STARTING UP 6 3 1 Pre start up Checklist 6 3 2 Starting the Pump 6 4 LOW ENERGY OPERATION 7 4 1 Using your Henden 3 Speed pump with a Henden Salt Water Chlorinator 7 4 2 Operating...

Page 4: ...s damaged it must be replaced by Henden or the manufacturer with genuine Henden spares This Henden 3 Speed Pump incorporates motor overload detection designed to protect the motor from overheating If...

Page 5: ...any humps and hollows which cause suction difficulties The discharge piping from the pump outlet should be connected to the inlet connection on the swimming pool filter usually at the filter control...

Page 6: ...minutes will automatically revert to the last used speed setting The pump can further be adjusted to run at different speeds between the three speeds 1 First prime the pump by removing the strainer ba...

Page 7: ...he flow rate is sufficient to cover your cell plates completely at all times of operation For other chlorinators please refer to the relevant installation and operating instructions 25 TOTAL HEAD m 20...

Page 8: ...d is tripped The pump has an in built thermal overload which will re set automatically after the motor has cooled following an overheating period Determine the cause of the overload tripping and recti...

Page 9: ...ould it be necessary to remove the pump follow these instructions 1 Switch off the power and remove the plug from the power source 2 Close the water valves on the pool return and the pump inlet pipewo...

Page 10: ...IRING MUST BE CARRIED OUT BY AN AUTHORISED ELECTRICIAN 10 HENDEN INSTALLATION OWNERS MANUAL Routine Maintenance tasks to maximise the life of your pool equipment personal safety use this checklist onc...

Page 11: ...r advertised failure to properly follow the provided installation and operating instructions failure to carry out maintenance corrosive or abrasive water or other liquid lightning or high voltage spik...

Page 12: ...P N 403212 2...

Reviews: