Henden 3 Speed Pump Installation Manual
HENDEN
INSTALLATION & OWNERS MANUAL
|
5
2. PIPE CONNECTION
A barrel union is provided for connecting to the piping
from the pool. The barrel unions are designed to accept
40mm PVC on the ID or a 50mm PVC fitting on the OD.
When plumbing the discharge pipe, ensure that the
pipework does not interfere with the touchpad’s
protective cover, which needs to fully open and close.
Ensure pipework from
discharge does not interfere
with protective cover.
Barrel unions need to be hand
tightened. No sealant, glues or
silicones are required.
The use of any pipe smaller than those specified above is
not recommended. Suction piping should be free from all
air leaks and any humps and hollows which cause suction
difficulties.
The discharge piping from the pump outlet should be
connected to the inlet connection on the swimming pool
filter (usually at the filter control valve).
ELECTRICAL DATA
Model
H83SP
RPM
Eco Flow Speed – 1400
Mid Flow Speed – 2400
High Flow Speed – 2850
Enclosure Class (IP)
24
Insulation Class
Class B 130 Insulation
Voltage (V)
240 AC
Supply Frequency (Hz)
50
Run current (A)
6.3
Motor Input Power (W / hp)
Eco Flow - 168W / 0.23hp
Mid Flow – 679W / 0.91hp
Hi Flow – 1,125W / 1.51hp
Motor Output Power (W / hp)
Eco Flow - 127W / 0.17hp
Mid Flow – 521W / 0.70hp
Hi Flow – 853W / 1.14hp
Operating Limits:
Max Water temperature
50°C
Max Ambient temperature
55°C
Dimensions:
Model
A
B
C
D
E
Mounting
Holes
Diameter
Inlet
PVC
Outlet
PVC
Net
Weight
(kg)
H83SP 645 330 250 305 246
10
*40/50 *40/50 15.9
A
B
C
D
E
*Suction and delivery accept 40mm PVC pipe on the I.D. and 50mm fitting on the O.D.