Important! In order to allow the specified retaining forces to be transferred in the best
way possible, the clamping sleeve's inside surface and the round rod's surface must be
thoroughly cleaned and any grease removed before installation.
If desired, limit switches possessing an M8 x 1 thread may be fitted. Select limit switches
with a low switching distance and low hysteresis (e.g. Sn 1.5 mm, hysteresis <10%).
Minimum screw-in depth for Size 63 = 19 mm, Size 80 = 22 mm, Size 125 = 27 mm.
The limit switches are exclusively for monitoring the condition, they are not suitable
for use as safety-relevant control systems.
The customer must implement suitable additional safety measures to prevent
malfunctioning or risks.
Important! Connections with high flow resistances (long, thin, tight radii, bends) may
affect response times.
High speed or fast ventilation valves can considerably reduce the response times of the
PClamp!
Never fit two or more PClamps above each other; HEMA supplies special solutions for
such requirements.
12. Installed state (sample)
!
!
!
!
PClamp
EN