Model 5314A
Operation

10 Hz/N=1

This switch, 

when 

IN, reroutes the Channel A input

by-10 prescaler circuit (when FREQ A/START A switch
MUST be used for frequencies between 

IO MHz 

an

quency, this switch, when 

IN, 

prescales the input signal by 

10

 and gives a

display with a 

10 

Hz resolution (prescale by 

10

 with a I-second gate time).

This switch and switch@ (1 Hz/N=lOO) IN prescales the input and gives a
display with a 

100 Hz 

resolution (prescale by 

IO 

with a 100-millisecond  gate

time). This switch and switch 

(IO 

Hz/N=1O) IN 

prescales the input and

gives a display with a 

kHz resolution (prescale by 10 with a IO-millisecond

gate time).

In Period, this switch 

IN 

causes the 

HP 5314A 

to measure 1 period and

display the value 

in microseconds (this switch is used 

for single-shot period

measurements).

In Ratio, this switch 

IN 

causes the 

HP 5314A 

to make 

measurement and

display the ratio (this switch 

is used 

for single-shot ratio measurements).

In Time Interval, this switch should be pressed. This programs the HP5314A

to make single-shot time interval measurements.

In Start, the HP 5314A counts the input directly (IO Hz to 10 MHz) and

displays in units. With this switch IN, the input is prescaled by 10 and the
display 

is in kilo units. 

This switch MUST be 

used in START A 

for signals

above 

10 MHz.

SLOPE This switch setting determines which slope of the Channel 

input signal

will be used as the triggering slope.

LEVEL A LEVEL control used in conjunction with the attenuator switch 

 to

select the relative voltage at which triggering occurs. Approximately
t350 millivolts is the amount varied. The input amplifiers are ac coupled.
The actual dc level of the trigger point is unknown.

INPUT A BNC connector for the 

channel signal input. The input impedance is

Meg. For more information on the input signal, refer to Table 7-7,

Specifications.

ATTN Channel A input signal attenuator switch. Used in conjunction with the

LEVEL control to set the trigger point. The input signal is not affected in 

Xl

position. Input signal amplitude is reduced by a factor of 20 in the X20
position.

 i SEP/COM A

INPUT B

Input amplifier control switch.

a. SEP - Allows independent operation of A and B channels.

b.

COM A - Operationally connects Channels A and B in parallel. Used
for single source time interval measurements. Channel B input jack
is not active. The input impedance remains the same as in 

SEP.

BNC 

connector 

for 

the B channel signal input. The input impedance is

Meg. For more information on the input signal, refer to Table 7-7,

Specifications.

SLOPE

LEVEL B

This switch setting determines which slope of the Channel B input signal
will be used as the triggering slope.

LEVEL control used to select the relative voltage at which triggering

occurs. 

When switch 

 is in SEP, 

the trigger voltage varies approxi-

mately 

 mV.

 When switch

is in COM A, the trigger voltage varies

approximately 

 mV times the attenuator (switch-a 

)

 setting. The

input amplifiers are ac coupled. The actual dc level of the triggering point
is unknown.

3-6

Figure 

3-2. 

Front

Panel 

Controls and 

Connectors (Continued)

Summary of Contents for 5314A

Page 1: ...ow This manual with enclosed Manual Changes sheet applies to HP Model 5314A having serial number prefixes as listed on the Manual Changes sheets Copyright H E W L E T T P A C K A R D C O M P A N Y 197...

Page 2: ...gh this instrument has been designed in accordance with international safety standards this manual contains information cautions and warnings which must be followed to ensure safe operation and to ret...

Page 3: ...h must be followed by the user to ensure safe operation and keep the HP 5314A in safe operating condition 1 8 INSTRUMENTS COVERED BY MANUAL I 9 If the serial number prefix of your HP 5314A is lower th...

Page 4: ...in decade steps of N for N l to 1000 Resolution LSD B Trigger Error X FREQUENCY A N Accuracy 1 count of A B Trigger Error X FREQUENCY A TOTALIZE A Range 10 Hz to 10 MHz Resolution t 1 count of input...

Page 5: ...for the HP 5314A They are a Temperature Compensated Crystal Oscillator TCXO Option 001 and a battery pack for portable operation Option 002 I 17 The seven functions are Frequency Single Shot Period P...

Page 6: ...for use during performance tests adjustments and troubleshooting Substitute test equipment may be used if it meets the required characteristics listed in the table Table 7 3 Recommended Test Equipmen...

Page 7: ...Time Interval Measurements 3 10 The counter measures time intervals from Channel A to Channel B that is Channel A starts the measurement and Channel B stops the measurement Time between points on a s...

Page 8: ...is the same Description numbers match the numbers on the illustration 3 22 OPERATOR S MAINTENANCE 3 23 There is no operator s maintenance for the HP 5314A All maintenance should be per formed by qual...

Page 9: ...2 battery charging circuit in the STBY position Front panel window allowing access to the oscillator frequency adjust ment capacitor AlC2 In HOLD switch IN the measurement except for totalize in progr...

Page 10: ...uses the HP 5314A to make 100 measurements and display the average ratio This switch does not improve accuracy beyond 100 nanoseconds for time interval measurements 0 I 10 Hz N 10 In frequency 10 Hz t...

Page 11: ...n with the attenuator switch 0 to select the relative voltage at which triggering occurs Approximately t350 millivolts is the amount varied The input amplifiers are ac coupled The actual dc level of t...

Page 12: ...ifi 6 Select either 1 Hz or 10 Hz NOTE 10 Hz resolution for frequencies between 10 Hz and 10 MHz may also be used For frequencies higher than 10 MHz the 100MHz 1O Hz switch must be pressed IN NOTE The...

Page 13: ...acy and amplitude 1 Set line switch to the ON position 2 Set COM A SEP switch to SEP position 3 Connect the input signal to INPUT A jack 4 Press PER A T l A B switch IN Make sure the blue shift key is...

Page 14: ...position 3 Press PER A T I A B switch 0 bottom function of switch 0 IN Press the blue shift key IN position This selects the 4 Connect the start time interval signal to the INPUT A jack Connect the st...

Page 15: ...EP position 3 Place the two function switches and in the OUT position This places the HP 5314A in the Ratio A to B function 4 Connect the higher frequency signal to the INPUT A jack D Connect the lowe...

Page 16: ...accuracy and amplitude 1 Set line switch to the ON position 2 Set COM A SEP switch 0 to SEP position 3 Press the FREQ A START A switch IN 4 Press the blue shift key IN position This selects the bottom...

Page 17: ...n the IN position The HP 5314A should display with the overflow LED 0 ON and the instrument gating once every second 4 Place resolution switch 10 Hz N 10 in the IN position The HP 5314A should display...

Reviews: