background image

Helvar

 

|

 

Helvar Oy Ab, Keilaranta 5 FI-02150 Espoo, Finland. Data is subject to change without notice. www.helvar.com  

LC45iC-DA-100-900 LED driver is suited for built-in usage in luminaires. With LC1x70-SR/LC-SRB/LC-SRB-LOOP strain relief, independent 
use is possible too. In order to have safe and reliable LED driver operation, the LED luminaires will need to comply with the relevant 
standards and regulations (e.g. IEC/EN 60598-1). The LED luminaire shall be designed to adequately protect the LED driver from dust, 
moisture and pollution. The luminaire manufacturer is responsible for the correct choice and installation of the LED drivers according to 
the application and product datasheets. Operating conditions of the LED drivers may never exceed the specifications as per the product 
datasheet. 

Installation & operation

Maximum ambient and t

c

 temperature

•  For built-in components inside luminaires,

 the 

t

a

 

ambient 

temperature range is a guideline given for the optimum 
operating environment. However, integrator must always 
ensure proper thermal management (i.e. mounting base of the 
driver, air flow etc.) so that the 

t

c

 point temperature does not 

exceed the 

t

c

 maximum limit in any circumstance.

•  Reliable operation and lifetime is only guaranteed if the 

maximum  t

c

 point temperature is not exceeded under the 

conditions of use.

LED driver earthing

•  LC45iC-DA-100-900

 is Class I LED driver suitable for Class I and 

II luminaires, as well as driving Class III (SELV) luminaire parts 
in independent installation with external strain relief.

•  If used inside 

Class I

 

luminaires, the earth cable is recommended 

to be connected to improve the EMC performance of the driver, 
but it is not mandatory. It is the responsibility of the integrator 
to ensure that the assembled luminaire EMC performance 
complies with the latest standards. Driver RFI measurement 
data will be provided by request.

•  If used inside 

Class II 

luminaires, the safety of the luminaire shall 

be ensured through double/reinforced insulation of live parts. 

LC45iC-DA-100-900

 has double/reinforced insulation between 

accessible and live parts, and is suitable for use in all Class II 
luminaires. In this case the earth terminal of the driver must 
be left unconnected and the luminaire terminal block shall not 
have any protective earthing terminal.

•  If used in 

independent

 installation with Class I/II/III luminaires, 

the earth cable connection is optional. Please follow the 
instructions provided in the strain relief datasheets.

Miniature Circuit Breakers (MCB)

•  Type-C MCB’s with trip characteristics in according to EN 60898 

are recommended.

•  Please see more details in “MCB information” document in each 

driver product page in “downloads & links” section.

Installation site

•  The general preferred installation position of LED drivers for 

independent use is to have the top cover facing upwards.

•  Minimum recommended distances below:

•  Suitable for installation upside down and in the corner, in this 

case  separate spacers must be used. For more information, 
please consult Helvar.

Helvar Driver Configurator -support

LC45iC-DA-100-900 LED driver is supported by Helvar Driver 
configurator software. The LC45iC-DA-100-900 driver supports 
output current setting with software, the output current of the 
driver can be programmed using Helvar Driver Configurator, as 
well as OEM customer data and parameters for functions such as 
CLO and Tunable White behavior.  Programming the driver with 
Helvar Driver Configurator can be done either wirelessly via NFC 
or then via DALI bus.

 23.06.2022     6/7

Information and conformity

T22 187 1A

Summary of Contents for LC45iC-DA-100-900

Page 1: ...ween circuits driver case Mains circuit SELV circuit Double reinforced insulation DALI circuit SELV circuit Double reinforced insulation Mains circuit DALI circuit Basic insulation Mains DALI and outp...

Page 2: ...temperature is not exceeded From 500 mA to 900 mA full dimming range 2 100 and wide CCT dynamic range available in the whole area From 100 mA to 500 mA the absolute minimum dimming level is limited to...

Page 3: ...rating window Cool white Dynamic range Warm white 1200 mA 500 mA Dynamic range in colour temperature control LC45iC DA 100 900 LED driver is ready to be used out of the box Highest precision and color...

Page 4: ...tity of drivers per miniature circuit breaker 16 A Type C CONVERSION TABLE FOR OTHER TYPES OF MINIATURE CIRCUIT BREAKER MCB type Relative quantity of LED drivers B 10 A 37 B 16 A 60 B 20 A 75 C 10 A 6...

Page 5: ...mA 5 45 W U LEDdc 12 50 V ta 25 50 C U OUT 60 V tc 75 C PRATED 17 5 W LED Driver LC45iC DA 100 900 220 240 V 50 60 Hz AC DC Made in Finland Ch1 Cool White Ch2 Warm White L N 5765000 WKYXXXXX No Earth...

Page 6: ...y It is the responsibility of the integrator to ensure that the assembled luminaire EMC performance complies with the latest standards Driver RFI measurement data will be provided by request If used i...

Page 7: ...r with short circuit protection SELV control gear Thermally controlled control gear incorporating means of protection against overheating to prevent the case temperature under any conditions of use fr...

Reviews: