Operating window
Driver performance
Operating Conditions and Characteristics
Absolute highest allowed t
c
point temperature
75 °C
Tc life (50 000 h) temperature
75 °C
Ambient temperature range*
–
25 °C
...
+50 °C*
in independent use
–
25 °C
...
+45 °C
Storage temperature range
–
40 °C
...
+80 °C
Maximum relative humidity
No condensation
Life time(90 % survival rate)
100 000 h, at t
c
= 65 °C
70
000
h,
at
t
c
= 70 °C
50
000
h,
at
t
c
= 75 °C
*) For other than independent use, higher t
a
of the controlgear possible as long as highest allowed t
c
point temperature is not exceeded
*From 500 mA to 900 mA, full dimming range ( 2 % - 100 %) and wide CCT dynamic range available in the whole area.
From 100 mA to 500 mA, the absolute minimum dimming level is limited to 10 mA of total current. Dimming / CCT
control possible all the way down to that current, but the dynamic range may be limited. Each single channel can dim
down to 0.5 mA level.
0
10
20
30
40
50
60
0,00
0,10
0,20
0,30
0,40
0,50
0,60
0,70
0,80
0,90
1,00
Ou
tp
ut v
ol
ta
ge
[V
]
Output current [A]
U
LED
(max), V
U
LED
(min), V
50,0
56,0
62,0
68,0
74,0
80,0
86,0
92,0
0
5
10
15
20
25
30
35
40
45
50
Effic
ie
nc
y
(%
)
Total output power (W)
Typical efficiency
900 mA
350 mA
0,65
0,70
0,75
0,80
0,85
0,90
0,95
1,00
0
5
10
15
20
25
30
35
40
45
50
λ
Total output power (W)
Typical power factor
900 mA
350 mA
23.06.2022 2/7
LC45iC-DA-100-900
T22 187 1A