Settings (available through Z-Wave network only) 

All configuration parameters are accessed through Z-Wave COMMAND_CLASS_CONFIGURATION 

Time Mode Schedule 

Parameters 41-44 

 Schedule Time

 

Use these Parameters to manual set the Morning, Day, Evening and Night times for the Temperature Schedule.

 

The value of these Parameters has format HHMM, e.g. for 08:00 use value 0800 (time without a colon). From 00:00 to 
23:59 can be selected. 

 

The factory default value for Morning (Parameter 41) is 0600.

 

The factory default value for Day (Parameter 42) is 0900.

 

The factory default value for Evening (Parameter 43) is 1800.

 

The factory default value for Night (Parameter 44) is 2300.

 

 

Parameters 45-72 

 Schedule Temperature

 

Use these Parameters to manual set the temperature for each day Schedule (see the Parameters table on the page 19 
of this manual). The value of this Parameter should be x10, e.g. for 22.5°C set value 225. From 1°C (value 10) to 37°C 
(value 370) can be selected. 
The factory default Morning temperature for all 7 days (Parameters 45, 49, 53, 57, 61, 65, 69) is 24.0°C (value 240).

 

The factory default Day temperature for all 7 days (Parameters 46, 50, 54, 58, 62, 66, 70) is 20.0°C (value 200).

 

The factory default Evening temperature for all 7 days (Parameters 47, 51, 55, 59, 63, 67, 71) is 23.0°C (value 230).

 

The factory default Nigh temperature for all 7 days (Parameters 48, 52, 56, 60, 64, 68, 72) is 18.0°C (value 180). 

Sensors Report Interval 

Parameter 141 

 Energy Consumption Meter Consecutive Report Interval

 

When the device is connected to the Z-Wave gateway (controller), it periodically sends to the gateway reports from its 
energy consumption sensor even if there is no change in the value. This Parameter defines the interval between 
consecutive reports of real time and cumulative energy consumption data to the gateway. The value can be adjusted 
from 1 min to 120 min. The factory default value is 10 min.

 

Note:

 If the consumption changes, the device will send the report to the gateway regardless of this Parameter value 

(the report will be sent according to value in Parameter 142). 

Note:

 In order not to increase traffic on your network, it is not recommended to reduce the value of this Parameter. We 

recommend reducing the value of this Parameter only in case of poor connection, when reports from the device does 
not always reach the gateway.

 

 
Parameter 142 

 Energy Consumption Report Threshold

 

This Parameter determines the change in the load power resulting in the consumption report being sent to the gateway. 
From 1 to 50 can be selected. Use the value 0 if there is a need to stop sending the reports. The factory default value is 
25. 

Note:

 When the thermostat is turning ON, the consumption data will be sent to the gateway once, even if the value of this 

Parameter is 0.

 

 
Parameter 143 

 Sensors Consecutive Report Interval

 

When the device is connected to the Z-Wave gateway (controller), it periodically sends to the gateway reports from its 
room & floor temperature, humidity and light sensors even if there are not changes in the values. This Parameter 
defines the interval between consecutive reports. The value can be adjusted from 1 min to 120 min. The factory default 
value is 10 min.

 

Note:

 If the sensor readings change, the device will send the report to the gateway regardless of this Parameter value 

(the report will be sent according to values in Parameters 144, 145 and 146).  

Note:

 In order not to increase traffic on your network, it is not recommended to reduce the value of this Parameter. We 

recommend reducing the value of this Parameter only in case of poor connection, when reports from the device does 
not always reach the gateway.

 

 

Parameter 144 

 Air & Floor Temperature Sensors Report Threshold

 

This Parameter determines the change in temperature level (in °C) resulting in temperature sensors report being sent to 
the gateway. The value of this Parameter should be x10, e.g. for 0.4°C use value 4. From 0.1°C (value 1) to 10°C (value 
100) can be selected. Use the value 0 if there is a need to stop sending the reports. The factory default value is 2 (0.2°C). 

Note:

 When the thermostat is turning ON, the sensor data will be sent  to the  gateway  once,  even  if the value of this 

Parameter is 0.

 

Note:

 It is recommended not to decrease the value of this Parameter, in order not to increase the load on your Z-Wave 

network traffic. 
 
 

 

 

Summary of Contents for HE-HT01

Page 1: ...HEATING THERMOSTAT HE HT01 USER MANUAL for Hardware v 12 Firmware v 2 2...

Page 2: ...k 9 Adding to Z Wave network 9 Removing from Z Wave network 9 Security 9 SmartStart 9 Firmware OTA Update 10 Z Wave Plus V2 Specifications 10 Associations 11 Settings Menu 11 Settings available throug...

Page 3: ...ng it always easy to read Highly configurable with automatic safety You can select one of six operation modes with individual set points either manually or by using a Z Wave controller gateway As a sa...

Page 4: ...NTC sensors range 1k to 100k Periodic measurements from o Internal temperature sensor o External floor temperature sensor o Internal humidity sensor o Internal ambient light sensor o Energy consumptio...

Page 5: ...ve the display unit and backplate of the HE HT01 from the packaging 3 FIRST ENSURE THE POWER IS OFF at the main circuit breaker and then test the wires with a probe or multimeter to verify Insert the...

Page 6: ...xt switch On the main power at the circuit breaker see photo above The HE HT01 will start up showing the original default factory settings 8 Remove the clear protective film from the display unit and...

Page 7: ...s for Morning Daytime Evening and Night For example the Morning Schedule could be set to 22 0 C starting at 6 00 The Day Schedule could then be set to 17 0 C at 9 00 when everyone has gone to work or...

Page 8: ...from all or part of the property for a length of time The factory default ECO Set Point is 20 0 C Note In your Z Wave gateway this mode will be shown as Energy Save Heat VAC Vacation Mode Away Use Va...

Page 9: ...wn 3 The current state of the network will display in the Parameter Value position upper right It should display InC Note If E L is displayed the HE HT01 is already Excluded 4 Start the Exclusion Mode...

Page 10: ...nauthenticated or S0 Association Group Info V3 highest granted S2 Authenticated S2 Unauthenticated or S0 Multi Channel Association V3 highest granted S2 Authenticated S2 Unauthenticated or S0 Thermost...

Page 11: ...corner of the LCD The top left corner will display the Parameter Number And the top right corner will display the Parameter Value To scroll through the menu press the Heating Element button to go up...

Page 12: ...cy list below Modification is possible only while the HE HT01 is not included to Z Wave network While the device is included the Antenna Icon is shown at the bottom right corner of the LCD main screen...

Page 13: ...e from the device menu Parameter 04 LPc Energy Consumption values This Parameter allows you to check the Cumulative and Real Time Energy Consumption of the connected load Display information follows t...

Page 14: ...h IDLE state OFF when the external input is open released If Parameter value 2 the external input will operate in Toggle Switch Reverse mode if the external input is shorted the Thermostat switches to...

Page 15: ...even though the floor temperature is higher than 30 C d If the room temperature is higher than 27 C the Heating Thermostat will enter IDLE mode even though the floor temperature is lower than 30 C Fac...

Page 16: ...set the value 12 The factory default value is 0 5 C 5 through Z Wave network Time Configurations Parameter 19 tCr Time Correction by Main Controller If this Parameter value 1 and the HE HT01 is connec...

Page 17: ...142 Note In order not to increase traffic on your network it is not recommended to reduce the value of this Parameter We recommend reducing the value of this Parameter only in case of poor connection...

Page 18: ...and is received If the Basic Set command value is 0 OFF state the HE HT01 will go to Manual MAN mode and switch Off the heating element IDLE mode If the Basic Set command is value is 0xFF ON state the...

Page 19: ...70 50 2 bytes Tuesday Day temperature valueX10 200 10 370 51 2 bytes Tuesday Evening temperature valueX10 230 10 370 52 2 bytes Tuesday Night temperature valueX10 180 10 370 53 2 bytes Wednesday Morni...

Page 20: ...be sent to you EXCEPT AS MAY BE OTHERWISE PROVIDED BY APPLICABLE LAW THIS LIMITED WARRANTY IS IN LIEU OF ALL OTHER COVENANTS AND WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY I...

Reviews: