Parameter 15 

(“FtH”) –

 Floor Temperature Maximum (Highest level)

 

This Parameter is the floor temperature high limit 

 reading the external NTC temperature sensor. It only comes into effect 

if AF or tF are selected as the source sensor in Parameter 11. The Parameter value can be selected from 2.0°C to 37.0°C. 
Through the Z-Wave network the value of this Parameter should be x10, e.g. for 22.5°C set the value 225. The factory 
default value is 32°C (320 through Z-Wave network). 

 

Note: 

The

 

FtH value cannot be lower than (FtL + 1)°C.

 

 

Parameter 16 (“FtC”) –

 Floor Temperature Calibration

 

This Parameter defines the offset value for floor temperature. If the external floor temperature sensor is not calibrated 
properly,  then  manual  calibration  can  be  made  by  adjusting  the  values  up  to  ±10.0°C.  This  value  will  be  added  or 
subtracted from the floor temperature sensor reading. Through the Z-Wave network the value of this Parameter should 
be x10, e.g. for 1.5°C set the value 15. The factory default value is 0.

 

 

Parameter 17 

(“AtC”) –

 Air Temperature Calibration

 

This Parameter defines the offset value for room air temperature. If the internal air temperature sensor is not correctly 
calibrated,  then  manual  calibration  can  be  made  by  adjusting  the  values  up  to  ±10°C.  This  value  will  be  added  or 
subtracted from the internal air temperature sensor reading. Through the Z-Wave network the value of this Parameter 
should be x10, e.g. for 1.5°C set the value 15. The factory default value is 0.

 

 

Parameter 18 

(“HyS”) –

 Temperature Hysteresis (HyS)

 

This  Parameter defines the hysteresis value for temperature control. The HE-HT01  will stabilize the temperature with 
selected hysteresis. For example, if the SET POINT is set for 25°C and HYSTERESIS is set for 0.5°C the HE-HT01 will 
change the state to IDLE if the temperature reaches 25.0°C, but it will change the state to HEATING if the temperature 
becomes lower than 24.5°C. The hysteresis can be changed from 0.2°C to 10.0°C range. Through the Z-Wave network 
the value of this Parameter should be x10, e.g. for 1.2°C set the value 12. The factory default value is 0.5°C (5 through 
Z-Wave network).

 

Time Configurations 

Parameter 19 

(“tCr”) –

 Time Correction by Main Controller

 

If  this  Parameter  value  =  1  and  the  HE-HT01  is  connected  to  a  Z-Wave  gateway,  the  HE-HT01  time  and  day  will  be 
periodically polled and corrected from the gateway. To switch off auto-correction set the Parameter value to 0. The factory 
default value is 1.

 

 

Parameter 20 

(“tFo”) –

 Time Format

 

Either 24 hour or 12-hour time formats may be selected. Parameter value 0 = 24 hour format, Parameter value 1 = 12 
hour (AM/PM) format. The factory default value is 0.

 

 

Parameter 21 

(“dAy”) –

 Day of the Week Manual Adjustment

 

This Parameter allows manually adjustment of the day of the week in case the HE-HT01 is not connected to any Z-Wave 
gateway or auto-correction is disabled (Parameter 19 value is 0). 1 = Monday, 2 = Tuesday, 3 = Wednesday, 4 = Thursday, 
5 = Friday, 6 = Saturday, 7 = Sunday. The factory default value is 1.

 

 

Parameter 22 

(“

tIA

”) –

 Time Manual Adjustment

 

This Parameter allows manual adjustment of Time. To select between hours and minutes press the 

Clock “ ” button

. To 

raise or lower the time, press the 

+

 and 

“–

 buttons.

 

Parameter 23 

(“tOn”) –

 Time Regulation ON Time

 

This Parameter defines floor HEATING time in minutes when Time Regulator (

“t”

“tA” 

or 

“t

F

) is selected as the source 

sensor in Parameter 11. Time values can be changed in the range from 10 to 240 minutes. The factory default value is 
30 minutes.

 

 

Parameter 24 

(“tOF”) –

 Time Regulation OFF Time

 

This Parameter defines floor IDLE time in minutes when Time Regulator (

(“t”, “tA” or “tF”

) is selected as the source sensor 

in Parameter 11. Time can be changed in the range from 10 to 240 minutes. Factory default value is 30 minutes.

 

 

Parameter 25 

(“dr1”) –

 Dry Time

 

This Parameter specifies how long in minutes the Heating Thermostat will be in HEATING mode when the DRY mode is 
selected. After this time the HE-HT01 will enter the mode specified in Parameter 26. The time range can be selected from 
5 to 90 minutes. Factory default time is 30 minutes.

 

 

Parameter 26 

(“dr2”) –

 Mode To Switch After Dry Mode Operation Completion

 

This Parameter indicates the mode that will be set when Dry Time (Parameter 25) passed: 1 = COM, 2 = TIME, 4 = ECO, 
5 = VAC, 6 = MAN mode with IDLE state. The factory default value is 1. 

Summary of Contents for HE-HT01

Page 1: ...HEATING THERMOSTAT HE HT01 USER MANUAL for Hardware v 12 Firmware v 2 2...

Page 2: ...k 9 Adding to Z Wave network 9 Removing from Z Wave network 9 Security 9 SmartStart 9 Firmware OTA Update 10 Z Wave Plus V2 Specifications 10 Associations 11 Settings Menu 11 Settings available throug...

Page 3: ...ng it always easy to read Highly configurable with automatic safety You can select one of six operation modes with individual set points either manually or by using a Z Wave controller gateway As a sa...

Page 4: ...NTC sensors range 1k to 100k Periodic measurements from o Internal temperature sensor o External floor temperature sensor o Internal humidity sensor o Internal ambient light sensor o Energy consumptio...

Page 5: ...ve the display unit and backplate of the HE HT01 from the packaging 3 FIRST ENSURE THE POWER IS OFF at the main circuit breaker and then test the wires with a probe or multimeter to verify Insert the...

Page 6: ...xt switch On the main power at the circuit breaker see photo above The HE HT01 will start up showing the original default factory settings 8 Remove the clear protective film from the display unit and...

Page 7: ...s for Morning Daytime Evening and Night For example the Morning Schedule could be set to 22 0 C starting at 6 00 The Day Schedule could then be set to 17 0 C at 9 00 when everyone has gone to work or...

Page 8: ...from all or part of the property for a length of time The factory default ECO Set Point is 20 0 C Note In your Z Wave gateway this mode will be shown as Energy Save Heat VAC Vacation Mode Away Use Va...

Page 9: ...wn 3 The current state of the network will display in the Parameter Value position upper right It should display InC Note If E L is displayed the HE HT01 is already Excluded 4 Start the Exclusion Mode...

Page 10: ...nauthenticated or S0 Association Group Info V3 highest granted S2 Authenticated S2 Unauthenticated or S0 Multi Channel Association V3 highest granted S2 Authenticated S2 Unauthenticated or S0 Thermost...

Page 11: ...corner of the LCD The top left corner will display the Parameter Number And the top right corner will display the Parameter Value To scroll through the menu press the Heating Element button to go up...

Page 12: ...cy list below Modification is possible only while the HE HT01 is not included to Z Wave network While the device is included the Antenna Icon is shown at the bottom right corner of the LCD main screen...

Page 13: ...e from the device menu Parameter 04 LPc Energy Consumption values This Parameter allows you to check the Cumulative and Real Time Energy Consumption of the connected load Display information follows t...

Page 14: ...h IDLE state OFF when the external input is open released If Parameter value 2 the external input will operate in Toggle Switch Reverse mode if the external input is shorted the Thermostat switches to...

Page 15: ...even though the floor temperature is higher than 30 C d If the room temperature is higher than 27 C the Heating Thermostat will enter IDLE mode even though the floor temperature is lower than 30 C Fac...

Page 16: ...set the value 12 The factory default value is 0 5 C 5 through Z Wave network Time Configurations Parameter 19 tCr Time Correction by Main Controller If this Parameter value 1 and the HE HT01 is connec...

Page 17: ...142 Note In order not to increase traffic on your network it is not recommended to reduce the value of this Parameter We recommend reducing the value of this Parameter only in case of poor connection...

Page 18: ...and is received If the Basic Set command value is 0 OFF state the HE HT01 will go to Manual MAN mode and switch Off the heating element IDLE mode If the Basic Set command is value is 0xFF ON state the...

Page 19: ...70 50 2 bytes Tuesday Day temperature valueX10 200 10 370 51 2 bytes Tuesday Evening temperature valueX10 230 10 370 52 2 bytes Tuesday Night temperature valueX10 180 10 370 53 2 bytes Wednesday Morni...

Page 20: ...be sent to you EXCEPT AS MAY BE OTHERWISE PROVIDED BY APPLICABLE LAW THIS LIMITED WARRANTY IS IN LIEU OF ALL OTHER COVENANTS AND WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY I...

Reviews: