PTM-1100
Operators
Manual
5
SETUP SCREEN
This screen is used to calibrate the system and set the scale value, this screen is password
protected. Password is 361.
JOB
– This displays the current loaded job.
PEAK TONNAGE
– Displays the peak tonnage value.
CAM INPUT
– Pilot is set when Cam input is on (high).
TRACK OUTPUT (V)
– Displays the track output voltage, this can be used to reset the cal
value if needed. This should not be used for Zero balance, as it cannot display negative
numbers.
SCALE
– Set for the capacity of the press.
HIGH TONNAGE
– Displays the current High Capacity Alarm Set point. Pilot is set when
there is a High tonnage alarm.
Pilot can be set and relay is off, if in calibrate mode.
LOW TONNAGE
– Displays the current Low Capacity Alarm Set point. Pilot is set when there
is a Low tonnage alarm.
Pilot can be set and relay is off, if in calibrate mode.
HOME
– Press to return to the main screen.
FAULT RESET
– Press to clear all displayed faults and fault relay outputs.
CALIBRATE/PEAK MODE
– This button will clear toggle the unit between peak and calibrate
modes. (In calibrate mode capacity alarm relay outputs are bypassed).
The system will
automatically switch back to peak mode after 5 minutes.