PTM-1100

  

Operators 

Manual 

 

  4

TOUCH SCREEN INTERFACE 

 

MAIN MENU 

 

Main menu allows you to access different area of the system. The PTM-1100™ features a 
touch screen display for easy navigation and operation of the system. Click or touch on the 
button you wish to access. 
 

 

 
JOB

 – Displays the current job. Press to go to job screen. 

 
PEAK TONNAGE

 – Displays the peak tonnage value.  

 

CAM INPUT

 – Pilot is set when Cam input is on (high). 

 

HIGH TONNAGE

 – Displays the current High Capacity Alarm Set point. Pilot is set when 

there is a High tonnage alarm. 

Pilot can be set and relay is off, if in calibrate mode.

  

 

LOW TONNAGE

 – Displays the current Low Capacity Alarm Set point. Pilot is set when there 

is a Low tonnage alarm. 

Pilot can be set and relay is off, if in calibrate mode.

 

 

SPM

 – Displays the current Strokes Per Minute, which is calculated based on the duration of 

time between cam pulses. 
 

HOME

 – This button is inactive on the main screen, but will return the user to the main 

screen when pressed. 
 

FAULT RESET

 – This button will clear all displayed faults and fault relay outputs.  

 

SETUP SCREEN

 – Pressing this will prompt the user for the Setup Password. By pressing 

the 0-9 number button the user can navigate to the keypad and enter the numeric password. 
Once entered, press the Enter (Carriage Return, in lower right corner). Then press OK and 
press the setup screen button again. The password privileges will automatically reset after 5 
minutes of screen inactivity. 

 
 
 
 

 

Summary of Contents for PTM-1100 Series

Page 1: ...1 HELM INSTRUMENT CO INC PTM 1100 USER MANUAL REV 1 JUNE 2010 Helm Instrument Company Inc 361 West Dussel Drive Maumee Ohio 43537 USA 419 893 4356 Fax 419 893 1371 www helminstrument com...

Page 2: ...ring or replacing any defective Product at no additional charge and returning Product to customer freight paid Repair parts and replacement Products shall be furnished on an exchange basis and shall b...

Page 3: ...IONS 3 CUSTOMER SUPPLIED POWER 3 CAM INPUT 3 HIGH LOW CAPACITY FAULT RELAY OUTPUT 3 STRAIN GAGE INPUT 3 TOUCH SCREEN INTERFACE 4 MAIN MENU 4 SETUP SCREEN 5 JOB RECIPE SCREEN 6 PTM MODULE 7 STRAIN GAGE...

Page 4: ...MODULE PTM is a single channel strain gage sensor input module to process the signal of the strain gage to analog output PTM provides Auto Zero feature patented by Helm Instrument Co Inc The Auto Zero...

Page 5: ...ded 24VDC and DC common or Use the supplied DC1 24VDC through a dry contact to A1 and connect DC2 0VDC to A2 This input can be triggered with a proximity switch or a PLC output This input is the look...

Page 6: ...t Low Capacity Alarm Set point Pilot is set when there is a Low tonnage alarm Pilot can be set and relay is off if in calibrate mode SPM Displays the current Strokes Per Minute which is calculated bas...

Page 7: ...capacity of the press HIGH TONNAGE Displays the current High Capacity Alarm Set point Pilot is set when there is a High tonnage alarm Pilot can be set and relay is off if in calibrate mode LOW TONNAG...

Page 8: ...e the desired recipe 1 20 UP ARROW Used to move to higher value recipe DOWN ARROW Used to move to lower value recipe HIGH TONNAGE Press to set the recipe High Capacity Alarm Set point LOW TONNAGE Pres...

Page 9: ...the module to the center Off position cycle the press and record developed tonnage 2 Adjust the gain pot CW and cycle the press again 3 Compare the Peak Output scaled value on the display meter to the...

Page 10: ...the Peak Capture for the new machine cycle Normal Operation After the set up and calibration have been completed the 3 position calibration toggle switch should be set to the lower A Z Auto Zero posi...

Page 11: ...PTM 1100 Operators Manual 9 PTM MODULE DRAWING...

Page 12: ...PTM 1100 Operators Manual 10 PTM MODULE WIRING...

Page 13: ...PTM 1100 Operators Manual 11 PTM MODULE SIGNAL DIAGRAM...

Page 14: ...PTM 1100 Operators Manual 12 PTM 1100 USER CONNECTIONS...

Reviews: