23
T4137 Digital Milliohm Meter
•
Four terminal measurement
•
Large LCD display
•
12V DC battery powered
•
Robust lightweight case
with O-ring seal
Technical Specification
Resistance Ranges
Range
Accuracy
0 to 200
Ω
in steps of 100µ
Ω
0 to 2000m
Ω
in steps of 1
Ω
0 to 20
Ω
in steps of 10
Ω
0 to 200
Ω
in steps of 100m
Ω
0 to 2000
Ω
in steps of 1
Ω
±0,5% of
reading
±2 digits
Test Current
1mA = 2000
Ω
range
10mA = 200
Ω
range
100mA = 2000m
Ω
range
Maximum Output
Voltage
20V rms
Test Current
Accuracy
±0,1%
Meter
Supplied With
Certificate of
Conformence
T860 3 phase & Motor Rotation
indicator
•
Determine rotation of unconnected motors
•
Heavy duty alligator clips
•
Open phase identification
Technical Specification
Operating Voltage
100 to 600VAC
Operating Frequency
45 to 75Hz
Circuit Structure
Electronic
Operating Temp
0ºC to 50ºC at 90º &
Humidity
Max relative Humidity
Power Consumption
(Correct)
± 14mA for motor
rotation field test
±7mA for Phase
rotation field indication
Meter
Supplied With
Certificate of
Conformence
TEL1TLB SOCKET/ELCB TESTER/POLARITY
•
Live on earth indication (LCD Display)
•
Polarity indication
•
Identifies 6 wiring conditions
•
Earth tripping function
•
TEL13L (British Type 13A)
•
Floating earth detection
•
Ready-board compatible
•
If wiring is incorrect and brass knob is touched, LCD will
display a floating earth
Technical Specification
Rated Tripping Current
10,15,20,25,30,35mA
Resolution
5mA
Operation Voltage
220V
T890 Safety 3 phase Detector (Non contact)
•
Clamps over wire insulation without contact on conductor
•
Auto off
•
Non contact sensor clips
•
Open phase and phase sequence
•
Magnets on back of unit to mount on metal surfaces
Accessories
Carry Pouch
Dimensions (mm)
118(L) x 69(W) x 38(H)
Weight
370g
Model Specification
Technical Specification
Operating Voltage
150 to 1000VAC
Operating Frequency
45 to 65Hz
Circuit Structure
Electronic
Operating Temp
-10ºC to 50ºC
Humidity
80%
Power Source
4 x 1.5 AA Batteries
Current consumption
15mA
Cable Length
Approx 800mm
NEW
Meter
Supplied With
Certificate of
Conformance
INSTRUMENTS |
For more specifications, refer to the Test Instruments Catalogue
Summary of Contents for ACADEMY T419