21
Pay attention that all fan parts are correct and firmly connected with each other
.
ONLY FOR THE QUALIFIED AND AUTHORIZED ELECTRICAN!
WARNING: Ensure this fan is not connected with the main power supply.
•
The water pipes of the atomizer unit can be connected directly to the elctrical switch box in the
corresponding connectors. Return and pressure water line are also to connect and to fixed.
•
The rear part of the electrical switch box is fastened with special screws. This must be opened only by
an authorized electrican to can make electric wiring and connection of the pipe lines and wires.
•
During the fixing of the connections make sure that the respective existing rubber seals are not
pinched and damaged. The rubber seals should be above the electrical switch box.
If all cables and pipes are fixed to each other, the rear cover can be set on the switch box and closed
and screwed tighten firmly.
Remember to fix the rear cover by tamper screws.
•
Put the pipe and electrical cable for the water pump connection through the hole of water tank
container.
•
Connect the pump pipe to the water pump.
•
Put the water pipe loose in the tank container.
•
Close the water tank container with the correspond cover.
Pay attention that all fan parts are correct and firmly connected with each other
.
Operating instructions:
Caution! Connect to the mains supply only after the fan has been fully
assembled.
•
Place the fan on a stable, flat and dry surface and look for a solid and safe stand and positioning.
•
Do not use the fan on smooth surfaces or ground. Danger of slipping and injury!
•
Check the fan is switched off and not connected to the power supply.
•
Check wether the water tank container is filled with the prescribed amount of water.
•
Insert the plug of the fan into a suitable socket outlet. The fan is ready to operate.
Operating function:
MIST
Switch Mist fan adjustment
O / I
ON / OFF
FAN
Switch Fan function
O / I
ON / OFF
Summary of Contents for 4005812802114
Page 2: ...2 ...