![Hella 8ES 004 417-231 Operating Instructions Manual Download Page 22](http://html1.mh-extra.com/html/hella/8es-004-417-231/8es-004-417-231_operating-instructions-manual_2121331022.webp)
22
4.7 Profi Charger operating steps
IMPORTANT NOTES
– Clean the battery terminals. If stud adapters are required, fasten them with the proper tool. Do not use the battery
clamps to tighten adapters.
– Use stud adapters on Side-Post and/or Truck batteries that are not in the vehicle.
– Never remove the clamps from a battery to abort an active charging session. Always push the Multi function ON/
OFF button shortly before removing the clamps.
– Do not leave clamps lying in battery acid.
– Clean up any acid spills immediately (e.g., with baking soda and water).
– Clamps must be cleaned after every use.
4.7.1. Connect Profi Charger to Battery
Connect the PROFI CHARGER charging clamps to the battery in accordance with all precautions and safety
instructions.
4.7.2. Connect to AC Power
Plug the PROFI CHARGER into a dedicated, grounded 16 Amp AC outlet.
Do not use an AC line cord adapter or extension cord.
Switch
on the charger.
4.7.3. Select Profi Charger modes
Use the Multi Function
ON/OFF button to activate charger and selecting the battery technology used for charging the
battery: Lead acid, AGM/SPIRAL, GEL, Power supply or Memory Saver After selecting one of the modes the charger
will start charging automatically. This is indicated by the
Orange LED.
4.8 Profi Charger-Functions
To charge the different battery technologies the PROFI CHARGER has got a button to select one
of the following:
Flooded Lead acid;
Calcium, Antimony
AGM / SPIRAL
GEL
Power Supply / Memory Saver
Battery technology
16,50 / 14,20
16,50 / 14,40
16,50 / 14,30
-
u Boost
Pulse 13,5 – 14,8
Pulse 13,5 – 14,8
Pulse 13,5 – 14,8
13,10
u Float