background image

CSC-Tool

Product Description

Intended Use

2  Product Description

2.1                                                       

Intended Use                                                                         

The Camera & Sensor Calibration Tool (CSC-Tool) is a system for 
calibrating driver assist systems suitable for all makes and models. 
Optional modules enable brand-specific adjustments of all kinds of 
systems. Therefore, in connection with a diagnostic tool from Hella 
Gutmann you are able to calibrate e.g. the front camera for the lane 
departure warning system, the radar sensor for the ACC (Adaptive Cruise 
Control) or the camera for adaptive headlights.

The CSC-Tool can be exclusively operated in combination with a Hella 
Gutmann diagnostic tool. Diagnostic tools from other manufacturers will 
not be supported.

2.2                                                       

Delivery Contents                                                                 

Pieces

Designation

1

CSC Panel

1

Cross member

1

Dipstick

2

Base support on 
caster wheels

5

Summary of Contents for CSC-Tool

Page 1: ... BD0053V0004EN0316S0 460 985 69 03 16 Operating Instructions en CSC Tool ...

Page 2: ... 5 2 2 Delivery Contents 5 2 3 Tool Description 7 3 Working with the CSC Tool 14 3 1 Precondition for the Use of the CSC Tool 14 3 2 Placing the CSC Panel in Front of the Vehicle 14 3 3 Placing the CSC Panel Centred in Front of the Vehicle 17 3 4 Placing the CSC Panel Parallel to the Vehicle 21 3 5 Adjusting the Height of the Reference Panel 25 4 General Information 28 4 1 Care and Maintenance 28 ...

Page 3: ...recautions stated below Furthermore pay attention to all general instructions from labour inspectorates trade associations and vehicle manufacturers as well as all laws legal ordinances and instructions which have to be commonly obeyed by a repair shop 1 2 Safety Precautions for the CSC Tool In order to avoid incorrect handling and injury to the user or destruction of the CSC Tool arising from thi...

Page 4: ...ition should also be engaged in automatic vehicles Protect vehicle against rolling away 1 4 Safety Precautions Laser There is a risk of injury through dazzling the eyes when working with the laser Therefore regard the following Do not direct the laser beam towards persons doors or windows Never look directly into the laser beam Ensure proper room illumination Avoid trip hazards Secure mechanical p...

Page 5: ...connection with a diagnostic tool from Hella Gutmann you are able to calibrate e g the front camera for the lane departure warning system the radar sensor for the ACC Adaptive Cruise Control or the camera for adaptive headlights The CSC Tool can be exclusively operated in combination with a Hella Gutmann diagnostic tool Diagnostic tools from other manufacturers will not be supported 2 2 Delivery C...

Page 6: ...delivered to ensure that it is not damaged Should you identify any damage to the package then open the package in the presence of the delivery service and check the CSC Tool for hidden damage Any transport damage to the package supplied and damage to the CSC Tool shall be registered in a damage report by the delivery service 2 Open the package supplied and check for completeness based on the deliv...

Page 7: ...CSC Tool Product Description Tool Description 3 Remove the CSC Tool from the packaging 4 Check the CSC Tool for damage and completeness 2 3 Tool Description 2 3 1 CSC Panel 7 ...

Page 8: ...Product Description CSC Tool Tool Description 8 ...

Page 9: ...10 EasyTouch 4 Cross member 5 Adjustment screws of the base support Use the adjustment screws to balance the level gauge of the base support 6 Level gauge Use the level gauge to check whether the base support is exactly horizontal 7 Set screw on reference panel Use the set screw to fix the reference panel at the appropriate height 8 Handle Use this handle to move the reference panel upwards or dow...

Page 10: ...ol Tool Description 2 3 2 HD 10 EasyTouch Designation 1 Handle This handle makes it easier to carry the HD 10 EasyTouch 2 Scale of the HD 10 EasyTouch Here you can check whether the CSC Panel is placed parallel to the vehicle 10 ...

Page 11: ...th cross connector 6 Set screw on shaft with cross connector Use this set screw to adjust the height of the shaft with cross connector 7 Laser module The actual value can be projected onto the scale of the cross member of the CSC Panel with the help of the laser 8 Protective cylinder set This protects the wheel rim from damage 9 Level gauge Use the level gauge to check whether the HD 10 EasyTouch ...

Page 12: ...ing bolt Use this to adjust and secure the laser module 3 Switch Switch the laser on and off 4 Battery compartment cover 2 type AA batteries can be inserted into the battery compartment 2 3 4 Replacing the Batteries Replacing the Type AA Batteries Proceed as follows to replace the batteries 1 Switch off the laser beam 1 with the switch 3 2 Remove the battery compartment cover 4 tilting it from the...

Page 13: ...CSC Tool Product Description Tool Description 3 Remove the batteries individually NOTE Pay attention to correct installation direction polarity 4 Reassembly in reverse order 13 ...

Page 14: ... 1 Precondition for the Use of the CSC Tool Regard the following in order to use the CSC Tool Vehicle system is working properly No trouble codes stored in ECU memories Possible vehicle specific preparations done Rear axle track properly adjusted 3 2 Placing the CSC Panel in Front of the Vehicle Proceed as follows to place the CSC Panel in front of the vehicle 1 Connect the diagnostic tool to the ...

Page 15: ...lange or tyre CAUTION Scratching of surfaces Damage to wheel rims Always attach the protective cylinder set to the rim flange or tyre NOTE The distance between the CSC Panel and the centre of the wheel can be measured with a yard stick not included in the delivery contents only if the HD 10 EasyTouch is attached horizontally and centred to the centre of the wheel 5 Install one HD 10 EasyTouch on t...

Page 16: ... connector 6 Now you can adjust the height of the shaft with cross connector 7 Align the shaft with cross connector 5 to the wheel centre 1 8 Align the scales of the HD 10 EasyTouch at a right angle 9 Use a yard stick not included in the delivery contents to measure from the centre of the wheel 1 to the rear edge see marking of the cross member 4 16 ...

Page 17: ...istance A indicated in the diagnostic tool to the centre of the wheel 1 11 Perform steps 6 to 10 for the second HD 10 EasyTouch Now the CSC Panel is placed correctly in front of the vehicle 3 3 Placing the CSC Panel Centred in Front of the Vehicle Proceed as follows to place the CSC Panel centred in front of the vehicle 17 ...

Page 18: ...Panel Centred in Front of the Vehicle 1 Attach one HD 10 EasyTouch on the left and right rear wheel respectively 2 Align the scales of the HD 10 EasyTouch at a right angle NOTE Ensure that the level bubbles of both HD 10 EasyTouch devices are centred 18 ...

Page 19: ... and right mirror covers 2 of the cross member 4 should be tilted upwards The scales of the cross member and mirrors are visible CAUTION Laser radiation Damage to destruction of the retina Never look directly into the laser beam 4 Switch on the laser beam 1 of the laser module 7 with the switch 3 19 ...

Page 20: ...ool CSC Tool Placing the CSC Panel Centred in Front of the Vehicle 5 Align the laser module 7 by turning the mounting bolt 2 on the scale of the cross member 4 The laser beam is indicated on the scale of the cross member 20 ...

Page 21: ...r module 7 By moving the CSC Panel laterally place the panel in a way that the left and right scale of the cross member 4 show the same values Now the CSC Panel is placed centred in front of the vehicle 3 4 Placing the CSC Panel Parallel to the Vehicle Proceed as follows to place the CSC Panel parallel to the vehicle 21 ...

Page 22: ...C Panel Parallel to the Vehicle 1 Align the laser beam 1 of the laser module 7 with the mirror 3 of the cross member 4 The laser beam will be reflected from the mirror to the scale of the HD 10 EasyTouch 2 Perform step 1 with the second laser beam 22 ...

Page 23: ... Placing the CSC Panel Parallel to the Vehicle 3 By axially turning the CSC Panel place the panel in a way that the left and right scale of the HD 10 EasyTouch show the same values Now the CSC Panel is placed parallel to the vehicle 23 ...

Page 24: ...g screws of the base support 5 to adjust the horizontal and the vertical level gauge 6 of the cross member 4 and CSC Panel accordingly The adjusting screws also prevent the CSC panel from slipping The CSC panel is held in place and can no longer be moved If the horizontal and vertical level gauges are centred and even you can adjust the height of the reference panel 24 ...

Page 25: ... as follows to adjust the height of the reference panel WARNING Movable reference panel Risk of injury or pinching Use only the handle to move the reference panel 1 Loosen the left and right set screws 7 on the back of the reference panel 1 2 Position the dipstick 9 on the floor Now you can adjust the height of the reference panel 25 ...

Page 26: ...he Height of the Reference Panel 3 Use the handle 8 to move the reference panel 1 up to the height indicated in the diagnostic tool 4 Check the height of the reference panel 1 using the color marking 10 5 Tighten the left and right set screws 7 26 ...

Page 27: ... Height of the Reference Panel 6 Slightly push the dipstick 9 upwards from the floor and fix it with the set screw of the measuring rod 9 Then it cannot be damaged when moving the CSC Panel again 7 Start the calibration in the diagnostic tool with 27 ...

Page 28: ...lating to used electrical and electronic appliances and the national statute governing the distribution return and environmental disposal of electrical and electronic appliances Waste Electrical and electronic Equipment WEEE regulation of 16 March 2005 we are obliged to take back this device distributed after 13 August 2005 at the conclusion of its service life and to dispose it in accordance with...

Page 29: ...68 9900 3999 Mail info hella gutmann com 4 3 Technical Data for Laser Module General data Ambient temperature Recommended 0 35 C Operating range 0 50 C Supply voltage 2 7 3 3 V DC Batteries 2x 1 5 V AA Laser Wavelength 635 nm Output 1 mW Class 2 Operating range 0 10 m 29 ...

Page 30: ...Notes CSC Tool Notes 30 ...

Page 31: ...CSC Tool Notes Notes 31 ...

Page 32: ...TIONS GMBH Am Krebsbach 2 79241 Ihringen GERMANY Phone 49 7668 9900 0 Fax 49 7668 9900 3999 info hella gutmann com www hella gutmann com 2016 HELLA GUTMANN SOLUTIONS GMBH 1 STUECK PIECE S 9XQ 460 985 691 Made in Germany ...

Reviews: