The respective channel has to be chosen with the keys MENU+
und MENU
–
.
If the Input Signal is in the clipping area, the display will show a
filled-out HELIX diamond. If there is no clipping, the HELIX dia-
mond is not filled out.
8.2.2 Channel-Setup
By using the the CHANNEL key, the respective menu can be selec-
ted. The output channels which have to be adjusted can be selec-
ted via the keys CH+ and CH
–
. Please chose the desired function
for each channel with the keys MENU+ and MENU–. The respec-
tive settings can be made with the keys UP and DOWN.
The menu
DELAY TIME
provides the possibility to change the
displayed unit. Use the key BASS EQ/ SLOPE/
DELAY
to select
between ms / cm / inch. Use the key BASS EQ/
SLOPE
/ DELAY
for the filter settings. The edge steepness can be adjusted bet-
ween 12 or 24dB.
- HPF........................... 40 Hz - 10 kHz
- LPF............................ 40 Hz - 10 kHz
- Subsonic Filter..........15 Hz - 30 Hz
- Bass EQ Level........... 0 dB - 18 dB
- Channel Trim Level...-6 dB - + 6dB
- Delay Time................0 - 14 ms / 480 cm / 189 inch
- Channel Routing....... FL > FR > RL > RR > FL
and FR mix > RL and RR mix
- Polarity..................... Normal > Invert
8.2.3 Bass-EQ-Setup / Bass-Equalizer-Setup
By using the key BASS EQ, the respective menu can be chosen.
Select the desired function with the keys MENU+ and MENU–. The
settings can be made via the keys UP and DOWN.
- Center Frequency......... 45 Hz - 60 Hz
- Bandwith..................... Narrow > Wide
8.3 Test Tone Mode
The
HELIX DXP-6
has a Test-Tone-Mode (white noise) in order
to test the loudspeaker connections and the balance settings of
each channel. Use the key TEST TONE to select the mode.
The channel which shall be tested can be selected via the keys
CH+ and CH–. Use the keys UP and DOWN to adjust the test-
tone-level. Use the keys ESC or TEST TONE to quit the Test-Tone-
Mode.
9 Default Settings
in order the restore the default settings of
HELIX DXP-6
, press
the ESC key for 5 seconds. Confirm the reset process with the
key MENU+ (=Y=yes). Press the key MENU– (=N=no) or ESC to
cancel the reset process.
10
english