6. Interval operation
The fan can be automatically operated in adjustable intervals. The intervals can be adjusted via DIP-switches 5 and 6.
In interval mode, the set overrun time corresponds to the running time. Interval operation starts after the last switch-
off process. In interval mode, the set overrun time corresponds to the running time. Interval operation starts after the
last switch-off process. The required ventilation is superordinate to interval operation. In case of intermediate required
ventilation, the started interval time will be reset and restarted after deactivation.
The stage assignment is configured with DIP-switches 7 and 8 (see following table)
7.1 Functional test - test mode:
When applying the supply voltage the fan is in the test mode for 1 minute. (Requirement: Factory setting of DIP-switch,
see wiring diagram SS-1081) In this case the activation delay and the overrun function is deactivated within the first
minute, or for a switching cycle.
DIP-switch
Assignment of time function to stage
Interval
7
8
off
off
Np times
Higher stage
on
off
Time at lower stage
Lower stage
off
on
Time at higher stage
Higher stage
on
on
Time at both stages
Higher stage
Summary of Contents for ultra Silence MiniVent M1/150 N / C
Page 18: ...DE MiniVent M1 150 N C Montage und Betriebsvorschrift 16 Notizen...
Page 19: ...DE MiniVent M1 150 N C Montage und Betriebsvorschrift 17 Notizen...
Page 36: ...MiniVent M1 150 N C EN Installation and Operation Instructions 16 Notes...
Page 37: ...MiniVent M1 150 N C EN Installation and Operation Instructions 17 Notes...
Page 54: ...FR MiniVent M1 150 N C Notice de montage et d utilisation 16 Notes...