Page 1: ...Explosionsgesch tzte Baureihen Explosion proof series MegaBox MB Radialventilatoren Centrifugal fans m EN Helios Ventilatoren MONTAGE UND BETRIEBSVORSCHRIFT INSTALLATION AND OPERATING INSTRUCTIONS DE...

Page 2: ...eb Seite 8 KAPITEL 4 INSTANDHALTUNG UND WARTUNG Seite 8 4 0 Instandhaltung und Wartung Seite 8 4 1 Reinigung Seite 8 4 2 Hinweise St rungsursachen Seite 8 4 3 Ersatzteile Seite 8 4 4 Stilllegen und En...

Page 3: ...tel und Feuchtigkeits in di ka to ren Der Lager ort muss ersch tterungsfrei wassergesch tzt und frei von Temperatur schwan kun gen sein Lagertemperatur 20 C bis 40 C diese Grenzwerte d rfen nicht bers...

Page 4: ...chender f rdiejeweiligeZonezugelassenerGer tekategorie ver wendet werden Weitere Informationen sind den einschl gigen Normen und Gesetzestexten zu entnehmen Vor allen Wartungs und Installationsarbeite...

Page 5: ...z erforderlich sein Ventilatoren die durch ihre Einbauweise z B Einbau in L ftungskan le oder geschlossene Aggregate gesch tzt sind ben tigen kein Schutzgitter wenn die Anlage die gleiche Sicherheit b...

Page 6: ...r Verpackung und vor Montagebeginn sind folgende Punkte zu berpr fen liegen Transportsch den vor Freilauf des Laufrades einheitlicher Abstand von Laufradkanten zu Geh use Luftspalt Mindestluftspalte s...

Page 7: ...terschutzdach MB WSD Zubeh r montiert werden Abb 5 Die MegaBox ist f r vollkommen freie v llig ungesch tzte Bewitterung nicht geeignet Das Wetterschutzdach ist aus verzinktem Stahlblech und zur Befest...

Page 8: ...undendienst kontaktieren Eigene Reparaturversuche sind strikt untersagt Type in mm Spaltbreite T r B Spaltbreite D se C MBD 160 4 Ex 160 min 2 0 2 MBD 160 2 Ex 160 min 2 0 2 MBD 180 4 Ex 180 min 2 0 2...

Page 9: ...e zu berpr fen Auf die Beachtung der diesen Ger ten noch speziell beiliegenden Vorschriften wird hingewiesen Anschlussdaten m ssen mit den An gaben des Motorleistungsschildes bereinstimmen Die Einf hr...

Page 10: ...gerungen Stromaufnahme Funktion der Sicherheitsbauteile falls vorhanden Es wird empfohlen ein Anlagenwartungsbuch zu f hren und die durchgef hrten Pr fungen und Pr fungsergebnisse einzutragen Die Erge...

Page 11: ...470 35 MBD 180 Ex 470 412 269 20 230 55 134 4 618 106 5 200 200 161 219 470 30 Type A B C D E F G H I J K L M N Gewicht bis max kg Abb 8 Ma e in mm MBD 280 Ex 625 537 360 85 295 140 171 5 853 142 5 3...

Page 12: ...ig 6 2 Motortypenschild Eine Kopie des Motortypenschilds befindet sich neben dem Typenschild Technischen Daten sind dem Motortypenschild zu entnehmen 6 3 Zubeh r f r Ex Ventilatoren Angaben zum Ex Zub...

Page 13: ...Verlegung nach VDE n JA 3 Mindestluftspalt gepr ft n JA Wert 4 Freier Lauf des Laufrades gepr ft n JA 5 Stromaufnahme gemessen vgl mit Typenschild n JA Wert 6 F rder und Drehrichtung gepr ft n JA 7 S...

Page 14: ...7 Fehlerschleifen Impedanz TN System oder Erdungswiderstand IT System ausreichend 8 Isolationswiderstand ist ausreichend 9 Die automatische elektrische Schutzeinrichtung spricht in zul ssigen Grenzwe...

Page 15: ...13 MegaBox MB Radialventilatoren Montage und Betriebsvorschrift DE...

Page 16: ...7 3 10 Commissioning Page 7 3 11 Operation Page 8 CHAPTER 4 MAINTENANCE AND SERVICING Page 8 4 0 Maintenance and servicing Page 8 4 1 Cleaning Page 8 4 2 Indications Fault causes Page 8 4 3 Spare part...

Page 17: ...ging plastic bag with desiccant and humidity indicators The storage location must be vibration free water tight and free from temperature fluctuations Storage temperature 20 C to 40 C and these limits...

Page 18: ...legal texts Before any maintenance or installation work or before opening the terminal compartment the device must be fully isolated from the power supply and secured against unintended restart The e...

Page 19: ...uarantees the same protection It should be noted that the operator will be held responsible for accidents occurring as a result of missing protection devices 2 3 Air flow direction and direction of ro...

Page 20: ...nts must be checked after the removal of packaging and prior to the start of assembly is transportation damage apparent free movement of the impeller uniform distance from impeller blade to casing air...

Page 21: ...on the outdoor cover hood MB WSD Accessories must be mounted Fig 5 The MegaBox is not suitable for completely unprotected exposure to the weather The outdoor cover hood is made of galvanised sheet ste...

Page 22: ...repair attempts are strictly prohibited NOTE ATTENTION m Type in mm Gap width door panel B Gap width nozzle C MBD 160 4 Ex 160 min 2 0 2 MBD 160 2 Ex 160 min 2 0 2 MBD 180 4 Ex 180 min 2 0 2 MBD 200 4...

Page 23: ...tic line enclosed with the protection switch Also observe the regulations especially enclosed with the device Electrical connection data must correspond to the motor type plate data The installation o...

Page 24: ...process Casing impeller surface coating e g rust paint damage Bearing noises Damage Vibrations Deposits of dirt Power consumption Function of the safety components if provided It is recommended that...

Page 25: ...180 Ex 470 412 269 20 230 55 134 4 618 106 5 200 200 161 219 470 30 Type A B C D E F G H I J K L M N Weight up to max kg Fig 8 Dimensions in mm MBD 280 Ex 625 537 360 85 295 140 171 5 853 142 5 315 31...

Page 26: ...ate A copy of the motor type plate is located next to the fan type plate Technical data is shown on the motor type plate 6 3 Accessories for explosion proof fans Information on explosion proof accesso...

Page 27: ...tallation to VDE n YES 3 Minimum air gap checked n YES Value 4 Unhindered running of impeller checked n YES 5 Current consumption measured cf type plate n YES Value 6 Airflow direction and direction o...

Page 28: ...hysical check visual check 7 Fault loop impedance TN system or earthing resistance IT system satisfactory 8 Insulation resistance is sufficient 9 Automatic electrical protective devices operate within...

Page 29: ...13 MegaBox MB Centrifugal fans Installation and Operating Instructions EN...

Page 30: ...14 MegaBox MB Centrifugal fans Installation and Operating Instructions EN...

Page 31: ...15 MegaBox MB Centrifugal fans Installation and Operating Instructions EN...

Page 32: ...OS Ventilatoren GmbH Co KG Lupfenstra e 8 78056 VS Schwenningen F HELIOS Ventilateurs Le Carr des Aviateurs 157 av Charles Floquet 93155 Le Blanc Mesnil Cedex CH HELIOS Ventilatoren AG Tannstrasse 4 8...

Reviews: