7
Casing types ELS-GUBA
Installation and Operating Instructions
4 .2 Flush-mounted casing ELS-GUBA with fire damper / also for second room
The flush-mounted casing ELS-GUBA with fire damper and airtight metal backdraught shutter are designed for installa-
tion in residential units with K90 or K90K requirements outside of appropriate shafts in connection with steel or steelflex
ducting. The discharge spigot to the top (DN 80) can easily be used to the back by using the conversion kit ELS-ARS
(accessories).
The electrical connection with the fan takes place via a plug contact integrated in the casing. A plaster protection cover
is included in the scope of delivery.
The casing can be converted for the ventilation of bathrooms
and
WCs in residential units by using the second room kit
ELS-ZS
(accessories) (see page 8, section 4.2 Installation Second room kit).
Flush-mounted casing ELS-GUBA: Conversion kit Discharge spigot to the back
Conversion of casing type ELS-GUBA with conversion kit
ELS-ARS
(accessories) for discharge spigot to the back.
Fig.5
Remove ramp
ë
from casing in direction of arrow. (The ramp has no other uses in this installation).
Fig.6
The discharge spigot
ä
with metal backdraught shutter is attached to casing with rivets (4 pcs).
Fig.7
Remove cover
ö
on back of casing by rotating (symbol
).
Push rivets (4 pcs) out of frame from below. Then remove discharge spigot
ä
downwards from the
casing.
Fig.8
Insert the discharge spigot
ä
into back of casing from inside. Insert the new rivets (4 pcs) in the frame to
fasten. Attach cover
ö
to top of casing by rotating (symbol
Ï
).
Fig .7
ä
Fig .5
ë
ä
Fig .6
ä
Fig .8
ö
ä
ö
FIRE PROTECTION
Z