20mm (3/4”)
∅
15mm (1/2”)
∅
20mm (3/4”)
∅
25mm (1”)
∅
25mm (1”)
∅
(3/4”)
∅
(3/4”)
25
PARALLEL CONNECTION OF MULTIPLE SYSTEMS
notes
1.
All the branch lines to the sto
-
rage tanks must have same
length and geometry (diame
-
ter of tube, curves… etc)
2.
Pressure drop (¢p) must be
almost the same in hot and
cold-water tubes
COLD WATER
INLeT
HOT
WATER
OUTLET
SERIAL CONNECTION OF MULTIPLE SYSTEMS
(It is recommended the installation of maximum five appliances)
In multiple connections where the electric
resistance is used, you should avoid connec
-
ting the electric resistance in the storage
tanks of the first two appliances. These
appliances will be used to pre-heat the water
for the consumption.
For this kind of installation (or for more than
three solar water heaters connected in a row)
you have to make a special request for 3/4”
inlets-outlets pipes on the storage tank. We
recommend you to use a maximum of five
appliances.
All the piping in 20 mm diameter.
COLD
WATER
INLeT
HOT
WATER
OUTLET