14
02A
14A
02
19
19
17A
After the filling of the closed circuit, it is
necessary to loosen the plug (17A) at
the top right hand of the collector, until it
starts dripping thermal fluid (for models
200, 260 and 300 with two collectors,
loose also the top pipe union (12) in order
to release the air from the collector(s).
Tighten back the plug (17A) and the col
-
lector connection (12) and check for their
complete water tightness.
Filling Instructions of the Closed Circuit with Thermal Fluid
(for the solar water heaters of closed circuit)
MODEL
CLOSED CIRCUIT
TOTAL CAPACITY
TEMPERATURE
- 5ºC
- 11ºC
- 18ºC
- 20ºC
- 27ºC
- 36ºC
NOVASUN
120 x 2.10m
2
9 lt
8 lt
1 lt
7 lt
2 lt
6 lt
3 lt
6 lt
3 lt
5,5 lt
3,5 lt
4,5 lt
4,5 lt
NOVASUN
160 x 2.60m
2
11 lt
10 lt
1 lt
9 lt
2 lt
7,5 lt
3,5 lt
7,5 lt
3,5 lt
6,5 lt
4,5 lt
5,5 lt
5,5 lt
NOVASUN
200 x 2.60m
2
13 lt
11,5 lt
1,5 lt
10,5 lt
2,5 lt
9 lt
4 lt
9 lt
4 lt
7,5 lt
5,5 lt
6,5 lt
6,5 lt
NOVASUN
200E x 4.20m
2
18 lt
16 lt
2 lt
14,5 lt
3,5 lt
12,5 lt
5,5 lt
12 lt
6 lt
10,5 lt
7,5 lt
9 lt
9 lt
NOVASUN
260 x 4.20m
2
21 lt
19 lt
2 lt
16,5 lt
4,5 lt
14,5 lt
6,5 lt
14 lt
7 lt
12,5 lt
8,5 lt
10,5lt
10,5 lt
NOVASUN
300 x 4.20m
2
22 lt
19,5 lt
2,5 lt
17,5 lt
4,5 lt
15,5 lt
6,5 lt
14,5 lt
7,5 lt
13 lt
9 lt
11 lt
11 lt
NOVASUN
300E x 5m
2
23 lt
20,5 lt
2,5 lt
18,5 lt
4,5 lt
16 lt
7 lt
15,5 lt
7,5 lt
13,5 lt
9,5 lt
11,5 lt
11,5 lt
RATIO
Water
Fluid
Water
Fluid
Water
Fluid
Water
Fluid
Water
Fluid
Water
Fluid
ANTIFREEZE PROTECTION RATIO TABLE FOR SOLAR WATER HEATERS
Please take into account also to the dilution table on the bottle of the antifreeze liquid.