27
Important Information:
Valid Address values for writing to DXD transducers are:
2-digit values 01 through 99.
BR
BAUD RATE
Command Description
Reads or writes the DXD Unit’s
Bits Per Second Rate
Command Type
READ Command
Read Command Syntax #01BR[CR]
Typical Read Command Response:
Outputs the Bits Per Second Rate as a 12-Character string
as shown below
br
Command Description
Writes the DXD Unit’s Bits Per
Second Rate
Command Type
WRITE Command
Write Command Synax
#01br38400[CR]
Typical Write Command Response:
fixed length
3 bytes
Char. Position
1
2
3
Response Char.
ACK CR
LF
After this response is received, the serial communications
port properties must be adjusted, or no further communica-
tions can take place. The bit rate can then be verified with the
BR command.
Important Information:
Valid Baud Rate values accepted by the “br” command are:
1200, 2400, 4800, 9600, 38400, 57600, 115200
If an invalid Baud Rate code in EEProm is detected, the
default BR becomes 2400BPS.
ED
EEPROM MEMORY MAP DUMP
Command Description
Returns the first 160 bytes of
EEProm memory as decimal
values. The Values returned are
formatted 16 bytes per line with
ack/nak + carriage return/line
feeds appended at the ends.
Command Type READ Command
Read Command Syntax #01ED[CR]
Typical Read Command Response:
All but the last line contain 65 characters including CR/LF.
The last line contains 66 characters due to the inclusion of
an ack.
001 000 000 000 000 001 000 000 000 000 000 000 000 000 003 006 [CR][LF]
003 000 000 013 128 000 128 000 000 089 000 005 000 000 031 006 [CR][LF]
003 000 000 016 082 001 128 000 000 000 000 000 000 000 003 007 [CR][LF]
000 000 000 000 000 001 000 000 000 000 000 000 000 000 003 025 [CR][LF]
000 000 000 000 000 001 000 016 000 000 000 000 000 000 003 000 [CR][LF]
000 000 000 000 000 001 000 000 000 000 000 000 000 000 003 000 [CR][LF]
000 000 000 000 000 001 000 000 000 000 000 000 000 000 003 000 [CR][LF]
000 000 000 000 000 001 000 000 000 000 000 000 000 000 003 093 [CR][LF]
000 000 000 000 000 001 000 000 000 000 000 000 000 000 003 006 [CR][LF]
000 000 000 000 000 001 000 000 000 000 000 000 000 000 003 015 [CR][LF]
Char. Position
1
2
3
4
5
6
7
8
9
10
11
12
Response Char.
B
R
=
9
6
0
0
ACK CR