![Heinrichs TMU Installation And Operation Manual Download Page 104](http://html1.mh-extra.com/html/heinrichs-0/tmu/tmu_installation-and-operation-manual_2119981104.webp)
Heinrichs Messtechnik GmbH
Page 104 of 122
OPERATING MANUAL TMU / UMC3
7.2.13.4
Reset system error
The integrated diagnostic system of the UMC3 transmitter distinguishes between two types of errors (see also
Section 8.2, “UMC3 transmitter error messages”). Self-test errors such as problems with a sensor line or
inconsistent parameter inputs are displayed as textual error messages. Once the error has been eliminated, the
message automatically disappears from the display. For further information, see Section 8.2.3.1, “Display of
self-test errors”.
Errors that are attributable to system memory or software, division by zero, or a fault in the electronics unit are
designated as system errors. These error messages are not reset automatically after the error (usually of very
brief duration) is eliminated. Before resetting a system error manually, we advise you to contact our technical
service department. For further information, see Section 8.2.3.1, “Display of self-test errors”.
Reset error
[no]
The setting “no” will be displayed and can be changed by toggling the arrow keys.
If the operator toggles to [yes] and confirms the action by pressing “
”, the error messages disappear from the
display. If the message reappears shortly after, contact our technical service department for help.
7.2.13.5
Factory Reset
With
this function, all
settings
which can be changed
by entering
the customer password
are
reset to
the
delivery status
by the manufacturer.
Simultaneously, all parameters are also reset
.
Exceptions
:
A changed
customer
password
is not reset.
Likewise,
the selected language
will remain unchanged
The
counter contents
are retained only
if
the counter unit
has remained
unchanged
.
Otherwise
, the
counter is
cleared and reset to
the original
unit.
Reset
[no]
By toggling to [yes] and confirming the selection by pressing the “
” key, all settings are reset.
After selection of [yes], the transmitter reboots. The communication between the BE2 control unit and the
transmitters electronics will be interrupted for approx. 5 seconds und hereafter synchronized again.