The magnetic-inductive flow velocity sensor PITe is be used to measure or monitor the volume flow of 
liquids with and without solids concentration, slurries, pastes and other electrically conductive media 
while minimizing pressure drops. The conductivity of the medium must be at least 50 µS/cm. Pressure, 
temperature, density and viscosity do not affect the volume measurements.  Small quantities of solid 
particles and small gas bubbles are also measured as part of the volume flow. A larger number of 
solid particles or gas bubbles will lead to incorrect measurements. Special electrodes are available for 
media that tend to form greasy films or crusts. 

To perform flow measurements, the PITe sensor must be operated with a Heinrichs Messtechnik 
transmitter of the UMF-x series, for example the UMF2 (B). The transmitter UMF2 (B) is a 
programmable transmitter that process the measurement data received from the sensor displaying the 
results on 

it’s

 built in control panel. Furthermore, it is capable of transmitting various types of 

measurement results via a communication interface. 

 

5  Safety aspects during commissioning and maintenance 

5.1  Use of this manual and targeted personnel 

This document contains all the necessary information to ensure a correct operation of the herein 
described product. The document is intended for use by qualified personnel. This means personnel 
who possess the necessary knowledge needed to ensure a safe operation of the device, such as 
electronics engineers, electrical engineers, or service technicians who are conversant with the safety 
regulations pertaining to the use of electrical and automated technical devices.  

Such personnel must be authorized by the facility operator to install, commission and service the 
product described herein. Before any work is carried out on the device, these operating instructions 
must first be thoroughly read and understood. 

The principle rules and regulations in the country of the operator must be observed. 

5.2  Intended use of the device 

 

 

 

Warning

 

The operator is responsible for ensuring that the material used in the sensor and 
housing is suitable for the application, and that such material meets the 
requirements for the fluid being used and the ambient site conditions. The 
manufacturer accepts no responsibility when inadequate material and housing are 
ordered. 

 

Warning

 

To ensure a correct and safe operation of the device, it must be shipped, stored, 
set up, mounted, operated and maintained correctly. 

Summary of Contents for PITe-Series

Page 1: ...Installation and operating manual Please read the instructions carefully and store them in a safe place Magnetic Inductive Flow Velocity Sensor PITe with UMF2 B...

Page 2: ...HE TRANSMITTER 8 6 3 1 Sensor versions 9 6 4 PERFORMANCE CHARACTERISTICS 9 7 INSTALLATION CONDITIONS OF USE 10 7 1 INSTALLATION REQUIREMENTS 10 7 1 1 Examples of installation positions 10 7 1 2 Immers...

Page 3: ...Heinrichs Messtechnik Installation and Operation Manual PITe Page 3 of 22 13 DECLARATION OF CONFORMITY 20 14 FINAL NOTES 22...

Page 4: ...rnings in this document are defined in the four categorised terms below and are aimed to prevent putting operators and maintenance personnel at risk or to avoid material damage The used terms have wit...

Page 5: ...ied out by qualified and authorised technicians only Heinrichs Messtechnik GmbH extends no express or implied warranty in regard to the applicability of the present document for any purpose other than...

Page 6: ...spects during commissioning and maintenance 5 1 Use of this manual and targeted personnel This document contains all the necessary information to ensure a correct operation of the herein described pro...

Page 7: ...improper operation of any product improper handling or use of any replacement part or from external electrical or mechanical effects overvoltage or lightning Any such improper operation use or handli...

Page 8: ...2 System configuration The magnetic inductive PITe UMF2 B flow measurement system consists of a sensor PITe which picks up an induced measuring signal from the medium flowing through the pipe with a k...

Page 9: ...ptor 40mm with M52x2 sensor locking with rotation lock DN25 PN40 Form B1 DIN EN1092 1 JIS 16K 1 class 150 300RF ASME B16 5 6 4 Performance Characteristics Measurement accuracy Q 30 FS 1 5 of actual ra...

Page 10: ...tandard the minimum straight run of pipe ahead of the inlet must be 10 pipe diameters 10 x DN and 5 pipe diameters following the outlet 5 x DN DN nominal diameter of pipe The limits for the product an...

Page 11: ...r is an additional safety feature for recognizing empty or partially filled pipes Caution There is the danger of accumulation of solids in the vacinity of a siphon The installation of a cleaning apert...

Page 12: ...selected so that the installation pipe with the sensor is continually filled with the medium This requirement can be met by using drains and check valves Installation of pumps To avoid negative pressu...

Page 13: ...threaded version Installing the flanged version 7 1 3 Earthing potential equalisation The sound grounding concept of the flowmeter is a necessity for both safety reasons as well as to ensure a faultle...

Page 14: ...be taken if the window of the transmitter enclosure becomes fogged over or discolored This is a sure sign that moisture water or product medium has seeped into the terminal compartment of the housing...

Page 15: ...8 4 Zero point calibration To ensure precise measurements are obtained zero point calibration is essential the first time the device is put into operation and before any regular operations is carried...

Page 16: ...2 B transmitter combination has not been performed by the manufacturer the necessary settings must be implemented in the transmitter before the sensor can operate correctly This applies in particular...

Page 17: ...gth as can be seen in the graphic below The unbraided strands must lie over the O ring whos function it is to press the braids of the outer shield onto the metal cable gland This O ring does not serve...

Page 18: ...Heinrichs Messtechnik Installation and Operation Manual PITe Page 18 of 22 11 Dimensions weight 11 1 Dimensional drawings Threaded version standard Flanged version optional...

Page 19: ...ng the following fluid Since the used fluid is potentially hazardous to water toxic corrosive combustible we have checked all cavities on the device to ensure that they are free of fluid residues wash...

Page 20: ...en entspricht We declare herewith in sole responsibility that the product described above is conform with the provisions of the following EU directives including all published changes and amendments a...

Page 21: ...linie Direktive Norm Ref Nr Standard Ref No DIN Ausgabe Edition Kurz Beschreibung Short Description UMF2 B PIT PITe 2014 30 EU EN 61000 6 2 2011 06 Immunity Industry X X X EN 61000 6 3 2012 11 Emissio...

Page 22: ...losed We plan to optimize and improve the products described and in so doing will incorporate not only our own ideas but also and in particular any suggestions for improvement made by our customers If...

Reviews: