Heinrichs PITe-Series Installation And Operating Manual Download Page 4

Heinrichs Messtechnik

 

Installation and Operation Manual PITe  

 

Page 4 of 22 

Introduction 

It is essential that you read these installation and operating instructions, as well 
as the associated UMF2 (B) transmitter operating instructions, prior to 
installation and commissioning of the device. If the necessary operating manuals 
are not at hand, you can download them free of charge from 

www.heinrichs.eu

.  

The device is to be installed and serviced only by a qualified technician.  

Custom designs and special applications are not be addressed in this manual. 

All devices are thoroughly tested and checked for order compliance and functionality prior to shipping. 
If however you have any queries or problems concerning your purchased product, please contact our 
head office in Cologne. 

Heinrichs Messtechnik GmbH accepts no liability for any loss or damage of any kind arising 
from improper operation of any product, improper handling or use of any replacement part, or 
from external electrical or mechanical effects, overvoltage or lightning. Any such improper 
operation, use or handling shall automatically invalidate the warranty for the product 
concerned. 

1.1  Hazard warnings 

The purpose of the hazard warnings listed below is to ensure the safety of the device operators and 
maintenance personnel, and that the flowmeter and any devices connected to it are not damaged. 

The safety advisories and hazard warnings in this document are defined in the four categorised terms 
below, and are aimed to prevent putting operators and maintenance personnel at risk, or to avoid 
material damage. The used terms have, with respect to this document and the products described 
within, the following meanings: 

Danger  

means that failure to take the prescribed precautions 

will result 

in death, severe bodily injury, or 

substantial material damage.

 

Warning 

means that failure to take the prescribed precautions 

could result 

in death, severe bodily injury, or 

substantial material damage. 

Caution 

means that failure to take the prescribed precautions 

could result 

in incorrect operation, malfunction 

or damage to the device. 

Note  

means that the accompanying text contains important information about the product, handling of the 
product or is about a section of the documentation that is of particular importance. 

1.2  Packaging / storage / transport 

Your flowmeter was manufactured in accordance with the highest quality standards and was 
thoroughly tested prior to shipment. Upon receipt, please conduct a visual inspection for possible 
damage that may have occurred during shipment.  If you discover any transit damage, please contact 
our head office in Cologne or the local sales office responsible for your area immediately. Besides a 
fault description, the type of device in question and its serial number will be required for any claim. 

Heinrichs Messtechnik shall not furnish guarantee for any repair work done without prior notice.  
Unless otherwise agreed on, the rejected parts must be made available to us in case a claim is made. 

Summary of Contents for PITe-Series

Page 1: ...Installation and operating manual Please read the instructions carefully and store them in a safe place Magnetic Inductive Flow Velocity Sensor PITe with UMF2 B...

Page 2: ...HE TRANSMITTER 8 6 3 1 Sensor versions 9 6 4 PERFORMANCE CHARACTERISTICS 9 7 INSTALLATION CONDITIONS OF USE 10 7 1 INSTALLATION REQUIREMENTS 10 7 1 1 Examples of installation positions 10 7 1 2 Immers...

Page 3: ...Heinrichs Messtechnik Installation and Operation Manual PITe Page 3 of 22 13 DECLARATION OF CONFORMITY 20 14 FINAL NOTES 22...

Page 4: ...rnings in this document are defined in the four categorised terms below and are aimed to prevent putting operators and maintenance personnel at risk or to avoid material damage The used terms have wit...

Page 5: ...ied out by qualified and authorised technicians only Heinrichs Messtechnik GmbH extends no express or implied warranty in regard to the applicability of the present document for any purpose other than...

Page 6: ...spects during commissioning and maintenance 5 1 Use of this manual and targeted personnel This document contains all the necessary information to ensure a correct operation of the herein described pro...

Page 7: ...improper operation of any product improper handling or use of any replacement part or from external electrical or mechanical effects overvoltage or lightning Any such improper operation use or handli...

Page 8: ...2 System configuration The magnetic inductive PITe UMF2 B flow measurement system consists of a sensor PITe which picks up an induced measuring signal from the medium flowing through the pipe with a k...

Page 9: ...ptor 40mm with M52x2 sensor locking with rotation lock DN25 PN40 Form B1 DIN EN1092 1 JIS 16K 1 class 150 300RF ASME B16 5 6 4 Performance Characteristics Measurement accuracy Q 30 FS 1 5 of actual ra...

Page 10: ...tandard the minimum straight run of pipe ahead of the inlet must be 10 pipe diameters 10 x DN and 5 pipe diameters following the outlet 5 x DN DN nominal diameter of pipe The limits for the product an...

Page 11: ...r is an additional safety feature for recognizing empty or partially filled pipes Caution There is the danger of accumulation of solids in the vacinity of a siphon The installation of a cleaning apert...

Page 12: ...selected so that the installation pipe with the sensor is continually filled with the medium This requirement can be met by using drains and check valves Installation of pumps To avoid negative pressu...

Page 13: ...threaded version Installing the flanged version 7 1 3 Earthing potential equalisation The sound grounding concept of the flowmeter is a necessity for both safety reasons as well as to ensure a faultle...

Page 14: ...be taken if the window of the transmitter enclosure becomes fogged over or discolored This is a sure sign that moisture water or product medium has seeped into the terminal compartment of the housing...

Page 15: ...8 4 Zero point calibration To ensure precise measurements are obtained zero point calibration is essential the first time the device is put into operation and before any regular operations is carried...

Page 16: ...2 B transmitter combination has not been performed by the manufacturer the necessary settings must be implemented in the transmitter before the sensor can operate correctly This applies in particular...

Page 17: ...gth as can be seen in the graphic below The unbraided strands must lie over the O ring whos function it is to press the braids of the outer shield onto the metal cable gland This O ring does not serve...

Page 18: ...Heinrichs Messtechnik Installation and Operation Manual PITe Page 18 of 22 11 Dimensions weight 11 1 Dimensional drawings Threaded version standard Flanged version optional...

Page 19: ...ng the following fluid Since the used fluid is potentially hazardous to water toxic corrosive combustible we have checked all cavities on the device to ensure that they are free of fluid residues wash...

Page 20: ...en entspricht We declare herewith in sole responsibility that the product described above is conform with the provisions of the following EU directives including all published changes and amendments a...

Page 21: ...linie Direktive Norm Ref Nr Standard Ref No DIN Ausgabe Edition Kurz Beschreibung Short Description UMF2 B PIT PITe 2014 30 EU EN 61000 6 2 2011 06 Immunity Industry X X X EN 61000 6 3 2012 11 Emissio...

Page 22: ...losed We plan to optimize and improve the products described and in so doing will incorporate not only our own ideas but also and in particular any suggestions for improvement made by our customers If...