Heinrichs Messtechnik

 

Installation and Operation Manual PITe  

 

Page 21 of 22 

 

    

Anhang N zur Konformitätserklärung 

    

Annex N of the Declaration of Conformity

 

 

N

o

. 16.4149.01

 

 

Produktbeschreibung: 

Product description: 

 

Magnetisch Induktiver Durchflussmessgerät UMF2 (B) für 
Verwendung mit der Sensorreihe PIT* und PITe* 

Magnetic inductive flowmeter UMF2 (B) for use with the 
sensor series PIT* and PITe*

 

 
 
Die Konformität mit den auf Seite 1 genannte Richtlinien diese Erklärung wird nachgewiesen durch die 
Einhaltung folgenden Normen (abhängig von Gerätvariant): 

Conformity to the Directives referred to on Page 1 of this Declaration is assured through the application of the 
following standards (depending on version of device): 

 

Richtlinie 

Direktive 

Norm –Ref. Nr. 

Standard / 
Ref. N

o

.

 

 
 

DIN- 

Ausgabe 

Edition 

Kurz  Beschreibung 

Short Description 

U

M

F

(B

P

IT

P

IT

e*

 

2014/30/EU 

EN 61000-6-2 

2011-06 

Immunity Industry 

EN 61000-6-3 

2012-11 

Emission residential 

EN 61000-4-2  

2009-12 

Immunity ESD 

 

 

EN 61000-4-4 

2013-04 

Immunity fast transients / Burst 

 

 

EN 61000-4-5 

2015-03 

Surge voltage immunity  

 

 

EN 61000-4-6 

2014-08 

Immunity conducted disturbances 

 

 

EN 61000-4-8 

2011-07 

Immunity to magnetic fields 

 

 

EN 61000-4-11 

2005-02 

Voltage variations 

 

 

EN 61000-4-29 

2001-04 

DC Voltage variations 

 

 

EN 55011 

2011-04 

Radio frequency disturbance 

EN 61326-1 

2011-07 

EMC requirements 

2014/35/EU  EN 61010 

2011-07 

Safety requirements 

 

 

 

X: Zutreffende Norm / Applicable Standard

 

 
 
 
 
Name und Anschrift der Benannte Stelle / 

Name and Address of the Notified Body 

 

TÜV-SÜD Industrie Service GmbH 
Westendstraße 199 
D-80686 München 
ID-Nr. / 

ID-N

o

.: RL 2014/68/EU: 0036 

 

Summary of Contents for PITe-Series

Page 1: ...Installation and operating manual Please read the instructions carefully and store them in a safe place Magnetic Inductive Flow Velocity Sensor PITe with UMF2 B...

Page 2: ...HE TRANSMITTER 8 6 3 1 Sensor versions 9 6 4 PERFORMANCE CHARACTERISTICS 9 7 INSTALLATION CONDITIONS OF USE 10 7 1 INSTALLATION REQUIREMENTS 10 7 1 1 Examples of installation positions 10 7 1 2 Immers...

Page 3: ...Heinrichs Messtechnik Installation and Operation Manual PITe Page 3 of 22 13 DECLARATION OF CONFORMITY 20 14 FINAL NOTES 22...

Page 4: ...rnings in this document are defined in the four categorised terms below and are aimed to prevent putting operators and maintenance personnel at risk or to avoid material damage The used terms have wit...

Page 5: ...ied out by qualified and authorised technicians only Heinrichs Messtechnik GmbH extends no express or implied warranty in regard to the applicability of the present document for any purpose other than...

Page 6: ...spects during commissioning and maintenance 5 1 Use of this manual and targeted personnel This document contains all the necessary information to ensure a correct operation of the herein described pro...

Page 7: ...improper operation of any product improper handling or use of any replacement part or from external electrical or mechanical effects overvoltage or lightning Any such improper operation use or handli...

Page 8: ...2 System configuration The magnetic inductive PITe UMF2 B flow measurement system consists of a sensor PITe which picks up an induced measuring signal from the medium flowing through the pipe with a k...

Page 9: ...ptor 40mm with M52x2 sensor locking with rotation lock DN25 PN40 Form B1 DIN EN1092 1 JIS 16K 1 class 150 300RF ASME B16 5 6 4 Performance Characteristics Measurement accuracy Q 30 FS 1 5 of actual ra...

Page 10: ...tandard the minimum straight run of pipe ahead of the inlet must be 10 pipe diameters 10 x DN and 5 pipe diameters following the outlet 5 x DN DN nominal diameter of pipe The limits for the product an...

Page 11: ...r is an additional safety feature for recognizing empty or partially filled pipes Caution There is the danger of accumulation of solids in the vacinity of a siphon The installation of a cleaning apert...

Page 12: ...selected so that the installation pipe with the sensor is continually filled with the medium This requirement can be met by using drains and check valves Installation of pumps To avoid negative pressu...

Page 13: ...threaded version Installing the flanged version 7 1 3 Earthing potential equalisation The sound grounding concept of the flowmeter is a necessity for both safety reasons as well as to ensure a faultle...

Page 14: ...be taken if the window of the transmitter enclosure becomes fogged over or discolored This is a sure sign that moisture water or product medium has seeped into the terminal compartment of the housing...

Page 15: ...8 4 Zero point calibration To ensure precise measurements are obtained zero point calibration is essential the first time the device is put into operation and before any regular operations is carried...

Page 16: ...2 B transmitter combination has not been performed by the manufacturer the necessary settings must be implemented in the transmitter before the sensor can operate correctly This applies in particular...

Page 17: ...gth as can be seen in the graphic below The unbraided strands must lie over the O ring whos function it is to press the braids of the outer shield onto the metal cable gland This O ring does not serve...

Page 18: ...Heinrichs Messtechnik Installation and Operation Manual PITe Page 18 of 22 11 Dimensions weight 11 1 Dimensional drawings Threaded version standard Flanged version optional...

Page 19: ...ng the following fluid Since the used fluid is potentially hazardous to water toxic corrosive combustible we have checked all cavities on the device to ensure that they are free of fluid residues wash...

Page 20: ...en entspricht We declare herewith in sole responsibility that the product described above is conform with the provisions of the following EU directives including all published changes and amendments a...

Page 21: ...linie Direktive Norm Ref Nr Standard Ref No DIN Ausgabe Edition Kurz Beschreibung Short Description UMF2 B PIT PITe 2014 30 EU EN 61000 6 2 2011 06 Immunity Industry X X X EN 61000 6 3 2012 11 Emissio...

Page 22: ...losed We plan to optimize and improve the products described and in so doing will incorporate not only our own ideas but also and in particular any suggestions for improvement made by our customers If...

Reviews: