HEINRICH
1.1.
Technical Specifications
Model
DVA8-500
DVA8-500RT
Description
Host
Extension Controller
AC Electrical Part
Power Supply
AC220V-250V, 50/60Hz
Power Consumption 650W
Max Current
<3A
Fuse
250V/5A, low speed type
DC Electrical Part
Power Supply
24V DC, 20V-27.5V
Max Current
<27A
Emergency
Microphone
Sensitivity
5mV
Impedance
600Ω
Line Input 1-6
THD
<1%, at rated power output, 1kHz
Sensitivity
775mV
Impedance
10kΩ
S/N Ratio
>70dB
Control Input &
Output
Fault Output
Closed circuit, no voltage
DVA6 State Output
Closed circuit, no voltage
DVA6 Reset Input
Closed circuit, no voltage, T>0.5s
8 Program Control
Output
Closed circuit, no voltage
8 Program Control
Input
Way-1: Closed circuit, no voltage
Way-2: Level input and max 3.3V
Emergency
Message
Format
WAV
Memory Card
SD memory card
Capacity
32G
Message No.
255 Max
Period
10 years
Log Event
Format
HEX
Storage Way
Nand Flash
Event No.
1000
Period
10 years
Working
Environment
Operation Temp
+5
℃
~ +40
℃
Storage Temp
-20
℃
~ +70
℃
Relative Humidity
< 95%
Mechanical Spec
Dimension
484(W)x132(H)x449(D)mm (3U)
Net Weight
11.5kg
Rack Mount
19” rack mount type
Finish
Aluminum plate and metal case in black
Summary of Contents for DVA8-500